RF-BM-BG22A3(I)
Shenzhen RF-star Technology Co., Ltd.
Page 10 of 26
3 Specifications
3.1 Recommended Operating Conditions
The functional operation does not guarantee performance beyond the limits of the conditional parameter values in the
table below. Long-term work beyond this limit will affect the reliability of the module more or less.
Table 4. Recommended Operating Conditions of RF-BM-BG22A3(I)
Items
Condition
Min.
Typ.
Max.
Unit
Operating Supply Voltage
DC-DC mode
2.2
3.3
3.8
V
Bypass mode
1.8
3.3
3.8
V
Frequency Range
2402
2480
MHz
Operating Temperature
/
-40
+25
+85
℃
Environmental Hot Pendulum
/
-20
+20
℃
/min
3.2 Handling Ratings
All measurements are based on the Silicon Labs reference design and datasheet.
Table 5. Handling Ratings of RF-BM-BG22A3(I)
Items
Condition
Min.
Typ.
Max.
Unit
Storage Temperature
Tstg
-40
+25
+125
℃
Human Body Model
HBM
±2000
V
Moisture Sensitivity Level
2
Charged Device Model
±500
V
3.3 Current Consumption
Table 6. Current Consumption of RF-BM-BG22A3(I)
Hardware Version: 1.0a
Test Date
May 14
th,
2020
Test Condition
F multimeter, load connects to DSA1030 spectrum analyzer, offset: 0.2,
RBW = 100 KHz
Stand-by
1
A
Transmitting Current
Set Tx Power
Actual Tx Power
Actual Current
0 dBm
-0.5 dBm
4.0 mA
Receiving Current
2.5 mA