HORNET 433MHz 

DS HORNET-13 

Pairing Transmitters to the HORNET-RXM (230Vac version)  

Please Note: During Learn and Erase the relays operate at high speed. They should be 

isolated from sensitive equipment during this process. 
 
To Pair additional Transmitter buttons to receiver Relay #1 
1. 

Apply power the receiver and wait 10secs for the unit to enter ‘normal operation’ 

mode. 
2.  Switch the receiver unit OFF and then ON again in ~1sec intervals FOUR times final-

ly leaving the unit powered. 

3. 

The receiver emits a continuous ‘Click’ to confirm it is now in ‘learn’ Mode

 

4.  Press the chosen transmitter button.  
5. 

The receiver will acknowledge by sounding the a single ’buzz’ 

 

6.  Learn Process complete.  
 
To Pair additional Transmitter buttons to receiver Relay #2 
1. 

Apply power the receiver and wait 10secs for the unit to enter ‘normal operation’ 

mode. 
2.  Switch the receiver unit OFF and then ON again in ~1sec intervals SIX times finally 

leaving the unit powered. 

3. 

The receiver emits a continuous ‘Click’ to confirm it is now in ‘learn’ Mode

 

4.  Press the chosen transmitter button.  
5. 

The receiver will acknowledge by sounding the two  ’buzzes’ 

 

6.  Learn Process complete.  
 
Erasing Receivers Memory  
1. 

Power the receiver unit up and wait 10 seconds for the unit to enter ‘normal opera-

tion’ mode.

 

2.  Switch the unit off and then on again at ~1 second intervals TEN times, leaving the 
unit powered. 
3. 

The receiver confirms Erase cycle complete by giving three short ‘Buzzes’

 

Configuring Receiver Relays 

The jumper links set the outputs to be Momentary (operates as long as transmitter is operated)  
or Latching (Relay changes state each time transmitter is pressed). 

The jumper links are made/removed by the small link ‘cap’ placed over the pin header. 

 

Link1 controls relay Output #1 
Link2 controls relay Output #2 
 
Link FITTED = MOMENTARY   
Link OPEN   = LATCHING 

Image shows,  
RLY1 Momentary,  
RLY2  Latching. 

JUMPER LINKS

LK2            LK1

Содержание Hornet-S1

Страница 1: ...variety of switching appli cations Transmitters may be added using the learn process any button on the transmitter can be used to control one or many outputs of the receiver Features Up to 100metres Range 4 Changeover Relays 12 30Vdc or 230Vac versions Reliable FM Technology Each output Rated 1000W Waterproof Enclosure to IP68 Momentary or Latching Relays Any Switch Map to Any Relay Output CE FCC ...

Страница 2: ... System 3 channel 433 92 100 HORNET RX Receiver 4 channel 433 92 Part Number Description Frequency MHz Range Metres HORNET S1M System 1 channel 433 92 100 HORNET S2M System 2 channel 433 92 100 HORNET RXM Receiver 2 channel 433 92 Bespoke Versions Custom versions available with your own logo and or protocol Please contact Sales for further info Range stated is optimum direct line of sight In worst...

Страница 3: ...2 The circuit board will then slide out 3 Connect to the screw terminals Live in Switched live out Pairing button Momentary latching settings link 1 2 Relay4 Relay3 Relay2 V 0V HORNET 12 32V Systems COM NO NC NO COM NC NO COM NC NO COM NC Power In 12 32Vac or dc GND Rx LED Learn LED Configuring Output Relays Momentary or Latching These are set by the Jumper Links Momentary operates as long as tran...

Страница 4: ...nce 3 The Learn LED will flash once to indicate relay 1 is selected 4 After the LED stops flashing press the Learn switch again to select the next relay channel 5 Repeat step 4 until the required relay is selected 6 Press the button on the transmitter you want to learn to the chosen relay 7 The Learn LED will flash to indicate Pairing is complete Pairing a Transmitter to a Receiver Each receiver h...

Страница 5: ...by removing the antenna and fixing screws from the base 2 The circuit board will then slide out 3 Connect to the screw terminals Warning The Receiver unit is designed to be a fixed installation connected to a mains supply Before removing the cover ensure that the mains input supply is removed Any opera tion of the product that involves removal of the cover should only be carried out by a Relay COM...

Страница 6: ...Switch the receiver unit OFF and then ON again in 1sec intervals SIX times finally leaving the unit powered 3 The receiver emits a continuous Click to confirm it is now in learn Mode 4 Press the chosen transmitter button 5 The receiver will acknowledge by sounding the two buzzes 6 Learn Process complete Erasing Receivers Memory 1 Power the receiver unit up and wait 10 seconds for the unit to enter...

Страница 7: ... used for isolation purposes ELECTRICAL CHARACTERISTICS Min Typical Max Units Supply Voltage for 12 30V versions 10 5 12 30 Vdc Supply Voltage for Mains versions 230 Vac Relay Rating 230Vac RLY1 4 5 rms 12 peak A Supply Current Quiescent 12V All relays operating 10 140 mA Supply Current 230V 13 mA Time delay from Tx on Switch to Rx Relay opera tion 100 mS Time delay from Tx sw relax to Rx Relay re...

Страница 8: ...F Solutions Limited et käesolev raadioseadme tüüp määratletud selles dokumendis vastab direktiivi 2014 53 EL nõuetele ELi vastavusdeklaratsiooni täielik tekst on kättesaadav järgmisel internetiaadressil www rfsolutions co uk FI RF Solutions Limited vakuuttaa että radiolaitetyyppi määratletud selles dokumendis on direktiivin 2014 53 EU mukainen EU vaatimustenmukaisuusvakuutuksen täysimittainen teks...

Отзывы: