Page 3
28-Aug-07
BlueLock DS377-10
© FlexiPanel Ltd
Patents Apply
www.FlexiPanel.com
Setting the Detection Range
The detection range may be set to any one of the
following settings:
Table 2. Detection Range Settings
Setting
Range
†
1
1.5 m / 5 ft
2
3 m / 10ft
3
5 m / 15 ft
4
9 m / 30 ft
5‡
15 m / 50 ft
6*
30 m / 90 ft
7*
50 m / 160 ft
†Ranges are approximate and depend
on actual operating environment.
*If device to be detected is Class II
The range may be limited to 10m-20m.
‡ Factory setting
To set the detection range:
1.
Press and hold down pushbutton SW1.
2.
Connect a jumper across SIL3 pins
b
and
c
. D5
will light until step 7.
3.
Release SW1.
4.
LED D4 will repeatedly show a series of flashes:
one flash indicates the current range setting is 1,
two flashes indicates setting 2, etc.
5.
Press pushbutton SW1 as many times as the
setting you want. For example, for setting 3,
press 3 times.
6.
LED D4 will repeatedly flash to show the new
setting.
7.
Remove the jumper link across SIL3.
Note that the detection range feature was added to
BlueLock in August 2007. If D5 does not light, the
device was manufactured prior to that date. Such
devices may be reprogrammed on request to enable
range setting. Contact FlexiPanel technical support
for details.