background image

Page 3

28-Aug-07

BlueLock DS377-10

© FlexiPanel Ltd

Patents Apply

 www.FlexiPanel.com

Setting the Detection Range 

The  detection  range  may  be  set  to  any  one  of  the 
following settings:

Table 2.  Detection Range Settings

Setting

Range

1

1.5 m / 5 ft

2

3 m / 10ft

3

5 m / 15 ft

4

9 m / 30 ft

5‡

15 m / 50 ft

6*

30 m / 90 ft 

7*

50 m / 160 ft

†Ranges are approximate and depend 

on actual operating environment. 

*If device to be detected is Class II 

The range may be limited to 10m-20m.

‡ Factory setting

To set the detection range:

1.

Press and hold down pushbutton SW1.  

2.

Connect a jumper across SIL3 pins 

b

 and 

c

.  D5 

will light until step 7.

3.

Release SW1.

4.

LED D4 will repeatedly show a series of flashes: 
one flash indicates the current range setting is 1, 
two flashes indicates setting 2, etc.

5.

Press  pushbutton  SW1  as  many  times  as  the 
setting  you  want.    For  example,  for  setting  3, 
press 3 times.  

6.

LED  D4 will  repeatedly  flash  to  show  the  new 
setting.  

7.

Remove the jumper link across SIL3. 

Note  that  the  detection  range  feature  was  added  to 
BlueLock  in  August  2007.    If  D5  does  not  light,  the 
device was  manufactured  prior  to  that  date.    Such 
devices  may be reprogrammed  on request  to enable 
range  setting.    Contact  FlexiPanel  technical  support 
for details.