DS 202-1
©2009 REG No 277 4001, Lewes, England. Page 5
Pairing Process
Pairing Process
Pairing Process
Pairing Process
Decide which input you wish to operate which output and follow the below process, bearing in mind
that LEDs on the 210-433F correspond directly to the relay out number on a connected relay board:
1.
Power the 210 receiver. On first use it will be in factory default mode—all channel LEDs
flashing alternately on/off.
2.
Power the 202 transmitter which you want to pair. Send a signal, by closing a switch or
contact across any input. Ensure that the 210 receiver comes out of factory default and flashes
LED 3 briefly.
3.
Once all LEDs are out, press the 210 receiver’s learn button once briefly then (all LEDs will
flash on then go out leaving only LED1 lit), tap the learn button repeatedly to scroll through the
LEDs 1-16, stop at the desired LED number leaving that numbered LED lit.
4.
Momentarily close the contact or switch on the 202 transmitter input that you wish to
pair to the selected 210 receiver output.
5.
The receiver’s output LED should flash to confirm that your chosen input is now paired to
the output required.
6.
Pairing is now complete for one channel, repeat for any other inputs or outputs required.
Erasing the Receiver Memory
Erasing the Receiver Memory
Erasing the Receiver Memory
Erasing the Receiver Memory
1.
To completely erase the 210 receiver memory, press and hold the learn button
2.
The learn LED (LED17) should illuminate (Fig 1.2)
3.
Hold the learn button for approximately 10seconds
4.
When the LED (LED17) extinguishes the memory is erased and the 210 receiver will return to
factory default mode.
Note: it is not possible to erase individual transmitters or inputs
.
Auto Tx
Auto Tx
Auto Tx
Auto Tx
When using the 202-433F channel 16 becomes permanently active. It will turn off if an Auto Tx signal
form the 202-433F fails to get through or if external power supply fails on the 202-433F Transmit-
ter.
AUTO TX fail on power supply fail can be disabled by switching the AUTO TX jumper link on the 202-
433F to the FORCE position.
NOTE:
NOTE:
NOTE:
NOTE: The Auto TX Channel does not need to be paired. If another pairing is made on this channel ena-
bling the Auto Tx feature would override it.