RF-LAMBDA
The power beyond expectations
20W Solid State
Power
Amplifier
6-18GHz
RFLUPA0618GB
Alarm
Status
Panel:
*LED needs to be manually reset to initial state by pressing RESET button
Name
Function
Initial
State
Description
Applied
RESET
Control
Manual reset button to reset PA
Yes
LED 1
POWER
Indicator
RED
Color
LED will light to RED color when
supply power is applied
Yes
LED 2
RF IN
Indicator
GREEN
Color
PA will shut down and latch this LED
to a RED color when input signal is
over limit *
Yes
LED 3
VSWR
Indicator
GREEN
Color
PA will shut down and latch this LED
to a RED color when output reflection
is over limit *
Yes
LED 4
ID
Indicator
GREEN
Color
PA will shut down and latch this LED
to a RED color when an imbalance in
the drain current of the combining
branches occurs or if a drain current
limit is reached *
Yes
LED 5
TEMP
Indicator
GREEN
Color
PA will shut down and latch this LED
to a RED color when driven over
temperature *
Yes