1701ULSA(EC)--EN, p. 11/30 

 

6

 

INSTALLING

 

WARNING

 

 

Check

 

the

 

supporting

 

structure

 

to

 

verify

 

that

 

it

 

has

 

sufficient

 

load

carrying

 

capacity

 

to

 

support

 

the

 

unit

 

weight.

  

 

Suspend

 

the

 

heater

 

only

 

from

 

the

 

threaded

 

nut

 

inserts.

 

Do

 

not

 

suspend

 

from

 

the

 

heater

 

cabinet

 

panels.

 

 

Do

 

not

 

place

 

or

 

add

 

additional

 

weight

 

to

 

the

 

suspended

 

heater.

 

 

 

 

The

 

location

 

where

 

the

 

air

 

heater

 

is

 

to

 

be

 

installed

 

must

 

provide

 

sufficient

 

space

 

around

 

the

 

heater

 

for

 

servicing

 

and

 

clearances

 

for

 

safety

 

(see

 

figure

 

2).

 

 

When

 

the

 

unit

 

is

 

lifted

 

for

 

suspension,

 

leave

 

the

 

unit

 

on

 

the

 

pallet.

 

Before

 

hanging

 

verify

 

that

 

all

 

screws

 

originally

 

used

 

to

 

fix

 

the

 

shipping

 

supports

 

are

 

re

screwed

 

into

 

the

 

cabinet.

 

 

Ensure

 

that

 

the

 

heater

 

is

 

installed

 

in

 

a

 

level

 

plane

 

and

 

vibration

 

free.

 

 

The

 

air

 

heater

 

must

 

be

 

fastened

 

securely

 

to

 

any

 

base

 

mounting

 

arrangement.

 

 

The

 

heater

 

is

 

supplied

 

with

 

four

 

point

 

suspension.

 

All

 

points

 

must

 

be

 

used.

 

Threaded

 

nut

 

inserts

 

are

 

provided

 

on

 

each

 

side

 

of

 

the

 

top

 

of

 

the

 

heater.

 

See

 

figure

 

4.

 

 

After

 

suspension

 

the

 

air

 

heater

 

should

 

be

 

rigid

 

so

 

as

 

to

 

avoid

 

placing

 

a

 

strain

 

on

 

the

 

flue

 

system,

 

gas

 

services,

 

electrical

 

wiring

 

and

 

duct

 

work.

 

1”

 

BSP

 

mounting

 

cap

 

nuts

 

are

 

optional.

 

 

In

 

case

 

of

 

a

 

type

 

C

 

installation,

 

the

 

distance

 

between

 

the

 

floor

 

and

 

the

 

underside

 

of

 

the

 

air

 

heater

 

must

 

be

 

at

 

least

 

1.70m.

 

Combustion

 

air

 

should

 

be

 

taken

 

from

 

a

 

height

 

that

 

exceeds

 

the

 

above

 

mentioned

 

height

 

of

 

1.70m.

 

Also

 

thermostats

 

and

 

switches

 

which

 

are

 

not

 

sparkless

 

have

 

to

 

be

 

installed

 

at

 

a

 

minimum

 

height

 

of

 

1.70m.

 

 

Figure

 

4

 

 
 

 

 
 
 
 
 
 

Be

 

sure

 

that

 

the

 

threaded

 

hanger

 

rods

 

are

 

locked

 

to

 

the

 

heater

 

as

 

illustrated

 

in

 

this

 

figure.

 

Recommended

 

maximum

 

hanger

 

rod

 

length

 

is

 

1.8m.

 

Where

 

longer

 

drops

 

are

 

required,

 

ensure

 

that

 

restraints

 

are

 

fitted

 

to

 

prevent

 

excess

 

lateral

 

movement

 

and

 

supports

 

are

 

adequately

 

sized.

 

Alternatively

 

the

 

unit

 

can

 

also

 

e

 

base

 

mounted

 

on

 

a

 

non

combustible

 

support.

 

In

 

this

 

case

 

ensure

 

that

 

unit

 

is

 

securely

 

fixed

 

on

 

the

 

base.

 

Содержание ULSA 025(EC)

Страница 1: ...ION COMMISSIONING SERVICING USER INSTRUCTIONS Applies to Belarus Bulgaria China Czech Republic Croatia Cyprus Denmark Estonia Finland Greece Hungary Iceland Latvia Lithuania Montenegro New Zealand Nor...

Страница 2: ...onnection Gas supply 17 10 Electrical connections 19 11 Commissioning lighting operation 21 12 Maintenance 23 13 Fault finding 25 14 Spare parts list 27 15 User instructions 27 16 Declaration of confo...

Страница 3: ...ledge unless they have been given supervision or instructions concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play wit...

Страница 4: ...The installation is not in accordance with these instructions Wiring is not in accordance with the diagram furnished with the heater Unit is installed without proper clearance to combustible material...

Страница 5: ...rge air along exposed walls with extra units provided to discharge air towards the centre of the area For optimum results heaters are best used in conjunction with recirculating air fans suspended at...

Страница 6: ...7 199 231 Protection grade IP Revolutions per minute rpm 950 1260 1340 820 1400 1 2 G 3 4 G See table 1b B22p C12 C32 C42 C52 C62 C82 Max thermal efficiency at max heat input G20 Max thermal efficienc...

Страница 7: ...0 I3B P 30 Finland I2H 20 I3B P 30 Greece I2H 20 I3P 37 Hungary I2H 20 I3B P 50 Iceland I2H 20 I3P 37 latvia I2H 20 I3P 37 Lithuania I2H 20 I3P 37 Montenegro I2H 20 I3P 37 New Zeeland I2H 20 I3P 37 No...

Страница 8: ...ir inlet D 4 Electrical connections 2 Flue connection D 5 Service panel 3 External gas connection C 6 Condensate drain ULSA ULSA EC A B C D E F I J K L M 025 738 1217 1 2 G 80 82 405 55 449 135 311 12...

Страница 9: ...p 9 30 Figure 1b ULSA ULSA EC 100 all dimensions in mm tolerance 3mm 1 Combustion air inlet 100mm 4 Electrical connections 2 Flue connection 100mm 5 Service panel 3 External gas connection 3 4 G 6 Co...

Страница 10: ...00 100 100 820 100 500 100 100 100 820 Heaters can be mounted on suitable non combustible supports 5 INTERNAL LAYOUT Figure 3 1 Metal mesh burner 2 Zero pressure regulator 3 Venturi 4 Differential pre...

Страница 11: ...suspension All points must be used Threaded nut inserts are provided on each side of the top of the heater See figure 4 After suspension the air heater should be rigid so as to avoid placing a strain...

Страница 12: ...cause unsafe conditions and or create condensation The units may be installed as a balanced flue type C heater requiring both a combustion air inlet pipe and a flue pipe or as a power vented heater ty...

Страница 13: ...all other relevant regulations rules in force Single wall flue pipe seamless aluminium stainless steel pipes are required All joints must be sealed to prevent products of combustion from leaking into...

Страница 14: ...1701ULSA EC EN p 14 30 Figure 7 Type C appliances combustion air and flue pipe sockets Vertical flue kit option 302 Horizontal flue kit option 301...

Страница 15: ...lation improved vapour barriers and weather proofing These practices mean that buildings are sealed much tighter than in the past Model ULSA ULSA EC 025 035 050 075 100 Max straight concentric length...

Страница 16: ...nt condensation water dripping from the drain pipe If you want to open the siphon e g to clean it the air heater must be shut down For security reasons it is recommended to wear gloves when cleaning t...

Страница 17: ...p with coupling must be mounted for servicing see figure 11 It is strongly recommended to place a gas filter and clean the gas tube with nitrogen The whole of the gas service installation including th...

Страница 18: ...he venturi Throttle adjustments and CO2 measurements will have to be made in order to obtain the recommended CO2 value For details please see the CO2 Throttle adjustment section 9 3 Attention Always c...

Страница 19: ...make connections to the terminals in the electric box as indicated on the wiring diagram Ensure that all cables and installers wiring are appropriately fixed and that they do not touch the flue combus...

Страница 20: ...ual on off control 0 or 100 functioning 2 By means of option 952 weekly programming digital chronothermostat GA11 used for remote control of several units consult option 952 instruction for more detai...

Страница 21: ...ed during a run cycle an automatic attempt for re ignition will take place If the burner does not relight safety shut down and lockout will occur Manual intervention to reset will be necessary to put...

Страница 22: ...ing which the combustion fan operates prior to activation of the ignition device The safety time is the delay between the gas valve being energised and the flame sensor checking for the presence of a...

Страница 23: ...ve all the dust from the combustion air fan with a soft cloth or brush 11 Check that the motor and the turbine are undamaged 12 Replace all parts in reverse order Substitution of bulb thermostat LC3 1...

Страница 24: ...el see removal of the service panel 4 Disconnect the electrical connections of the air circulation fan These connections are on the electrical connections terminal see the wiring diagram 5 Loosen the...

Страница 25: ...e unit is grounded earthed YES Connect ground wire to unit chassis Replace flame sensor Replace control module YES YES In case of a LL net swap the 2 lines NO Check if the igniter sparks Check presenc...

Страница 26: ...ameters YES Replace Pressure switch NO Check copper pipe inside the unit is not clogged Replace copper tube Check if the cooling fan works within set parameters NO Replace cooling fan NO Check if the...

Страница 27: ...35 100 reset switch 60 61988 2645 all signal lamp 60 61997 all pressostat 30 60621 13 605 all venturi gas valve 03 25700 003 0 0 3 025 venturi gas valve 40cm tube 03 25700 051 0 51 035 venturi gas val...

Страница 28: ...ing reset button inside the appliance or the remote control b check if thermal overheat control requires resetting 7 If the thermal overheat control requires resetting and doing so restarts the air he...

Страница 29: ...1701ULSA EC EN p 29 30 16 DECLARATION OF CONFORMITY...

Страница 30: ...1701ULSA EC EN p 30 30 NORTEK GLOBAL HVAC Belgium nv J M Sabbestraat 130 A000 B 8930 Menen Belgium Tel 32 0 56 52 95 11 www reznor eu...

Отзывы: