Reznor S6BQ-090 Series Скачать руководство пользователя страница 2

2

IMPORTANT SAFETY INFORMATION

Please read all information in this manual thoroughly and 

become familiar with the capabilities and use of your appliance 

before attempting to operate or maintain it. Pay attention to 

all safety warnings and any other special notes highlighted in 

the manual. Safety markings are used frequently throughout 

this manual to designate a degree or level of seriousness 

and should not be ignored.

WARNING

 indicates a potentially hazardous situation that if 

not avoided, could result in personal injury or death.

CAUTION

 indicates a potentially hazardous situation that 

if not avoided, may result in minor or moderate injury or 

property damage.
Keep this literature where you have easy access to it in the 

future. If a problem occurs, check the instructions and follow 

recommendations given. If these suggestions don’t eliminate 

your problem, call your servicing contractor. 

Do not attempt 

to repair or service this unit yourself!

 WARNING:

This equipment contains liquid and gaseous 

refrigerant under pressure. Installation and 

servicing should only be attempted by qualified, 

trained personnel thoroughly familiar with the 

equipment and safe responsible refrigerant 

handling procedures. Failure to comply with 

this warning could result in equipment damage, 

personal injury, or death.

 WARNING:

To avoid possible equipment damage, fire, 

or death, the following instructions must be 

observed regarding unit maintenance and 

operational procedures.

•  To achieve optimum performance and minimize equipment 

failure, it is recommended that periodic maintenance be 

performed on this unit. The ability to properly perform 

maintenance on this equipment requires certain mechanical 

skills and tools. Please consult your dealer for maintenance 

information and availability of maintenance contracts.

•  The area around the cooling unit a must be kept clear 

and free of combustible materials, gasoline, and other 

flammable vapors and liquids. Do not store or use flammable 

items such as paint, varnish, or strippers in the vicinity of 

the unit.

•  Do not use the area around the unit as a storage area. 

This area must be kept clean and clear of loose or exposed 

insulation materials. Examine the unit’s area when it is 

installed or when insulation is added, since some insulation 

materials may be combustible.

•  The top and sides of the unit must be open and clear of 

obstructions for proper airflow. Do not place anything on 

top of the fan grille or within 18 inches of all 4 sides of the 

unit. These clearances must be maintained to achieve 

rated performance. Do not use the area around the unit 

as a storage area.

•  Do not use this appliance if any part has been under water. 

Immediately call a qualified service technician to inspect 

the unit and to replace any part of the control system and 

any gas control which has been under water.

• Familiarize yourself with the controls that shut off the 

electrical power to the unit. If the unit needs to be shut down 

for an extended period of time, turn off electrical power 

at the circuit breaker. For your safety always turn off the 

electrical power before performing service or maintenance 

on the unit.

ABOUT THE AIR CONDITIONER

The S6BQ series air conditioner is designed only for outdoor 

rooftop or ground level installations. This unit has been tested 

for capacity and efficiency in accordance with AHRI Standards 

and will provide many years of safe and dependable comfort, 

providing it is properly installed and maintained. Abuse, 

improper use, and/or improper maintenance can shorten the 

life of the appliance and create unsafe hazards. A regular 

service and maintenance schedule should be established to 

ensure efficient and safe operation of the unit.

OPERATING INSTRUCTIONS

A 2-Stage Heat/Cool thermostat is required for proper 

operation of this equipment.

 

The thermostat should be 

mounted about 5 feet above the floor on an inside wall and 

not on an outside wall or other location where its operation 

may be adversely affected by radiant heat from fireplaces, 

sunlight, or lighting fixtures, and convective heat from warm 

air registers or electrical appliances.
Thermostat styles vary. Some models may not include the 

AUTO mode and others will have the AUTO in place of the 

HEAT and COOL. Others may include all three. Please refer 

to the thermostat’s User Manual for detailed programming 

instructions.

Cooling Operation (2-Stage Operation)

1. Set the thermostat’s system mode to COOL or AUTO and 

change the fan mode to AUTO. See Figure 1.

2. Set the thermostat temperature selector to the desired 

temperature level. Stage 1 cooling (low speed) will 

energize the outdoor fan, compressor, and indoor blower. 

Compressor and indoor blower will operate on low speed 

and will cycle on and off to maintain the indoor temperature 

at the desired cooling level. If indoor temperature is not 

satisfied the thermostat will energize stage 2 and the 

compressor and indoor blower motor  will ramp to high 

speed operation until load conditions are met  and cycle 

as required.

NOTE:

 If the temperature level is re-adjusted, or the system 

mode is reset, the fan and compressor in the outdoor unit 

may not start immediately. A protective timer circuit holds 

the compressor and the outdoor fan off for approximately 5 

minutes following a previous operation or the interruption of 

the main electrical power.

Heating Operation (Optional Electric Heat)

1. Set the thermostat’s system mode to HEAT or AUTO and 

change the fan mode to AUTO. See Figure 1.

2. Set the thermostat temperature selector to the desired 

temperature level. The indoor blower and optional electric 

heat module will cycle on and off to maintain the indoor 

temperature at the desired heating level.

Содержание S6BQ-090 Series

Страница 1: ... these instructions thoroughly before using the equipment Follow all precautions and warnings contained within these instructions and on the unit Improper installation adjustment alteration service or maintenance can cause personal injury or property damage Refer to this manual For assistance or additional information consult a qualified installer or service agency Do not store or use gasoline or ...

Страница 2: ...to replace any part of the control system and any gas control which has been under water Familiarize yourself with the controls that shut off the electricalpowertotheunit Iftheunitneedstobeshutdown for an extended period of time turn off electrical power at the circuit breaker For your safety always turn off the electricalpowerbeforeperformingserviceormaintenance on the unit ABOUT THE AIR CONDITIO...

Страница 3: ...aning the unit Proper maintenance is important to achieve optimum performance from the air conditioner The ability to properly perform maintenance on this equipment requires certain mechanical skills and tools If you do not possess these skills contact your dealer for maintenance Consult your local dealer about the availability of maintenance contracts Routine maintenance should include the follow...

Страница 4: ...rcuitsupplying the equipment Resetting circuit breakers or other switches Adjusting or calibrating of thermostat Specifications illustrationssubjecttochangewithoutnoticeorincurringobligations 01 18 O Fallon MO Nortek Global HVAC LLC 2018 All Rights Reserved 10131310 NEW TROUBLESHOOTING Before you call a Technician check the following Check the thermostat setting Make sure the system mode and tempe...

Отзывы: