42
962 Control Troubleshooting
Alarms
The Model 962 continuously monitors itself and sounds
an alarm if it detects something wrong. The alarm is a
beep that is on for one second and then off for nine
seconds.
When the alarm sounds, the display shows the letters
“Err” with a number from 1 to 4. The table below lists
the Err numbers, a description of each error, the cause
of the error, and the solutions. To silence the alarm,
press any button on the control. If the error still exists,
the control will go back to the alarm condition after 30
seconds.
Model 960 Alarms
Indication
Description
Cause
Solution
Err1
Electronics Failure
Control settings need
reprogramming.
Press any key to load default values. Refer
to “Programming the Model 960 Control”.
Err2
Improper start of
regeneration (limit switch
closed when it should be
open).
Valve camshaft has been
manually rotated during a
regeneration.
Valve camshaft has been
manually rotated out of
“regeneration complete”
position.
Faulty motor.
Faulty motor drive.
Faulty switch.
Press any key to silence the alarm. (Note:
Alarm automatically clears at “TIME OF
REGEN”.)
The control will turn the motor on and drive
the camshaft to the proper location.
Replace the control.
Replace the control.
Replace the control.
Err3
Improper finish of
regeneration (limit switch
open when it should be
closed).
Valve camshaft has been
manually rotated out of
“regeneration complete”
position.
Faulty motor.
Faulty motor drive.
Faulty switch.
The control will turn the motor on and drive
the camshaft to the proper location.
Replace the control.
Replace the control.
Replace the control.
Err4
Improper control settings
(one or more settings out of
the allowable range).
One or more settings out of
the allowable range.
Hardness: Adjust range: 3 to 250.
Capacity: Adjust range: 0.1 to 140.0.
Refill control: Adjust range: 1 to 99.
Brine draw value: Adjust range per
Table 4.1.
Problem
Possible Cause
Solution
1. Capacity display stays at 9999
even through there is water
usage.
a.
Total system capacity was calculated to
be a value greater than 9999.
a.
As the water usage continues, the remaining
capacity will drop below 9999 and then other
values will be shown.
2. Timer beeps when left arrow
button is pressed.
a.
Button is only active in the programming
mode.
a.
Refer to the Programming section.
3. Timer does not respond to
REGEN button.
a.
Button is not active in the programming
mode.
a.
Refer to the Regeneration section.
4. Timer does not display time of
day.
a.
Transformer is unplugged.
b.
No electric power at outlet.
c.
Defective transformer.
d.
Defective circuit board.
a.
Connect power.
b.
Repair outlet or use working outlet.
c.
Replace transformer.
d.
Replace control.
5. Timer does not display correct
time of day.
a.
Outlet operated by a switch.
b.
Power outages.
a.
Use outlet not controlled by switch.
b.
Reset Time of Day.