WARNING 

 
 

Before Operation 

 

 

The  manual  contains  vital  and  essential  information.  The  owner  should  read  and  understand  this 

important document before operating the charger. Contact REYA if you do not understand a statement. 

 
 

Before Installation 

 

 

In  order  to  avoid  overcharging  or  irreversible  damage  to  the  materials,  please  follow  closely  all 
recommendations cited  below. Do  not  install this  system near  inflammable materials. An owner  should 

seek guidance from an authorized DOLPHIN dealer or the factory. 

 

Do not install this system near a heat source 

 

It should not be installed in an airtight or badly ventilated area.  

 

All ventilation ducts must be unobstructed 

 

Mount in a vertical position, to create natural ventilation for the charger. Note that the wiring connections 
are  at  the  bottom  of  the  charger.  Leave  at  least  three  inches  clearance  above  and  below  the  unit  for 

proper ventilation. 

 

This system should not be exposed to water or dust. 

 

It is strictly forbidden to tamper with the system casing. 

 

 

Connecting the Unit 

 

 

In order to avoid all risk of electric shock or irreversible damage to the unit, please follow very carefully 

the following recommendations 

 

This  unit  is  set  to  be  connected  to  a  mono  phase  network  230V  50Hz  or  115V  60Hz  by  means  of  an 

internal switch. 

 

Do not attempt this selection unless the device is switched off. The position of the switch must follow the 

main power supply conditions. 

 

In order to protect the occupants, the input point must be attached to a circuit breaker. Please refer to 

the specific characteristics of the circuit breaker. 

 

For  security  reasons,  the  system's  PE  terminal  must  strictly  be  connected  to  the  installation's  Earth 

(green/yellow wire in the cable section) 

 

To prevent overheating, ensure the correct connection of cables. 

 

NB: If reverse polarity of the batteries occurs, the battery fuses will automatically blow. 

 
 

Start up precautions 

 

 

In order to prevent all risk of electric shocks at either start up or during the utilization of this system, the 

protection cap must rest in place and be tightly screwed. 

 

 

Maintenance precautions 

 

 

In order to prevent risk of electric shocks during maintenance, please follow closely all recommendations 

below before any maintenance begins. 

 

Disconnect the cable 

 

The access to -DC or -BAT must be disconnected in order to avoid transfer of energy. 

 

Please  wait  five  minutes  before  accessing  the  casing  as  the  high-voltage  capacitors  will  need  time  to 

discharge. 

 

Fuses must be replaced by fuses that have the same characteristics and performance levels. 

 

 

Содержание DOLBB.1210-2

Страница 1: ...12V 10A 12V 20A R f DOLBB 1210 2 R f DOLBB 1220 3 TECHNICAL NOTICE English version page 2 NOTICE TECHNIQUE Version fran aise page 6 REYA 144 Avenue de la Roubine 06156 CANNES LA BOCCA Tel 33 04 93 90...

Страница 2: ...mmendations This unit is set to be connected to a mono phase network 230V 50Hz or 115V 60Hz by means of an internal switch Do not attempt this selection unless the device is switched off The position...

Страница 3: ...bat Output voltage sharing 2 Output ripple 1 Max output current 10A 5 20A 5 Output fuse Fast 15 Amps Fast 25 Amps Protections Against output overload and short circuit over temperature 12V20A only an...

Страница 4: ...PERATURE FAULT Led off Internal temperature fault Check the installation and climatic conditions Check the internal fan is operational Check charger s confinement Connection DC DC1 DC2 DC3 Fuse Charge...

Страница 5: ...of the ventilation system and certain electrical components may result Modifications made to the casing and in particular if holes are bored may result in the deposit of metallic shavings or filings...

Страница 6: ...mple Pr cautions de raccordements Afin de pr venir tout risque de choc lectrique ou de dommage irr versible sur le mat riel veillez suivre de mani re imp rative les recommandations ci dessous Cet appa...

Страница 7: ...at I bat Tol rance tensions 2 Ondulation r siduelle 1 Courant de charge 10A 5 20A 5 Fusible de sortie F15A F25A Protections En cas de surcharge et court circuit en sorties de temp rature interne exces...