Rexroth IndraDrive FCS01.1
Error Messages
12-1
DOK-INDRV*--FCS01*****-IB01_EN-P
12 Error
Messages
Errors can cause deactivation of the frequency converters.
There are the following options for reset of an error (error confirmation):
•
by mains deactivation and re-activation,
•
by a correspondingly programmed digital input (P420… P424 =
function 12),
•
by removing the "release" at the frequency converter (when no digital
input has been programmed for confirming),
•
by a bus confirmation, or
•
by P506, the automatic error confirmation.
12.1 Indicator Elements at the FCS01 Basic Device
In factory setting, there are 2 LEDs (green/red) under the cover. They
signal the current status of the device.
The
green LED
signals the application of mains voltage; during operation,
it indicates the degree of overload at the frequency converter output by
means of an increasingly fast flash code.
The
red LED
signals pending errors by flashing the number of times
which corresponds to the numeric code of the error.
12.2 Indication in the Function Modules FCC01.1T-xxx
The standard control panel indicates an error with the respective error
number, preceded by an "E". Additionally, the current error can be viewed
in parameter P700. The last error messages are saved in parameter
P701. For more information on the frequency converter status at the
moment of error, refer to parameters P702 to P706.
If the error cause does not exist any more, the error indication at the
standard control panel will flash. Then, the error can be confirmed by
pressing the Enter key.
Содержание IndraDrive Fc FCS01
Страница 28: ...5 2 Delivery Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Страница 34: ...6 6 Certifications and Types Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Страница 56: ...8 20 Installation Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Страница 88: ...10 4 Commissioning Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Страница 237: ......