ment works. Do not operate the machine if the emergency stopping
switch is not working.
●
Prevent unintended start-up. Isolate the drive power connection by
means of OFF switches/OFF buttons or use a safe starting lockout.
●
Make sure that the drives are brought to safe standstill before accessing
or entering the danger zone.
●
Additionally secure vertical axes against falling or dropping after switch‐
ing off the motor power by, for example,
–
mechanically securing the vertical axes,
–
adding an external braking/arrester/clamping mechanism or
–
ensuring sufficient counterbalancing of the vertical axes.
●
The standard equipment motor holding brake or an external holding
brake controlled by the drive controller is not sufficient to guarantee per‐
sonal safety!
●
Disconnect electrical power to the components of the electric drive and
control system using the master switch and secure them from reconnec‐
tion ("lock out") for:
–
Maintenance and repair work
–
Cleaning of equipment
–
Long periods of discontinued equipment use
●
Prevent the operation of high-frequency, remote control and radio equip‐
ment near components of the electric drive and control system and their
supply leads. If the use of these devices cannot be avoided, check the
machine or installation, at initial commissioning of the electric drive and
control system, for possible malfunctions when operating such high-fre‐
quency, remote control and radio equipment in its possible positions of
normal use. It might possibly be necessary to perform a special electro‐
magnetic compatibility (EMC) test.
3.3.4
Protection Against Magnetic and Electromagnetic Fields During Oper‐
ation and Mounting
Magnetic and electromagnetic fields generated by current-carrying conduc‐
tors or permanent magnets of electric motors represent a serious danger to
persons with heart pacemakers, metal implants and hearing aids.
Health hazard for persons with heart pacemakers, metal implants and hear‐
ing aids in proximity to electric components!
●
Persons with heart pacemakers and metal implants are not allowed to
enter the following areas:
–
Areas in which components of the electric drive and control sys‐
tems are mounted, commissioned and operated.
–
Areas in which parts of motors with permanent magnets are stored,
repaired or mounted.
●
If it is necessary for somebody with a heart pacemaker to enter such an
area, a doctor must be consulted prior to doing so. The noise immunity
of implanted heart pacemakers differs so greatly that no general rules
can be given.
●
Those with metal implants or metal pieces, as well as with hearing aids,
must consult a doctor before they enter the areas described above.
DOK-GEAR**-GTE********-PR08-EN-P
Rexroth GTE Planetary Gearboxes
Bosch Rexroth AG
17/83
Safety Instructions for Electric Drives and Controls
Содержание GTE Series
Страница 6: ...Bosch Rexroth AG DOK GEAR GTE PR08 EN P Rexroth GTE Planetary Gearboxes IV 83 ...
Страница 26: ...Bosch Rexroth AG DOK GEAR GTE PR08 EN P Rexroth GTE Planetary Gearboxes 24 83 ...
Страница 32: ...Bosch Rexroth AG DOK GEAR GTE PR08 EN P Rexroth GTE Planetary Gearboxes 30 83 ...
Страница 58: ...Bosch Rexroth AG DOK GEAR GTE PR08 EN P Rexroth GTE Planetary Gearboxes 56 83 ...
Страница 68: ...Bosch Rexroth AG DOK GEAR GTE PR08 EN P Rexroth GTE Planetary Gearboxes 66 83 ...
Страница 78: ...Bosch Rexroth AG DOK GEAR GTE PR08 EN P Rexroth GTE Planetary Gearboxes 76 83 ...
Страница 82: ...Bosch Rexroth AG DOK GEAR GTE PR08 EN P Rexroth GTE Planetary Gearboxes 80 83 ...
Страница 85: ...Notes DOK GEAR GTE PR08 EN P Rexroth GTE Planetary Gearboxes Bosch Rexroth AG 83 83 ...