19.3 Appendix III: Parameter List
19.3.1 Terminology and Abbreviation in Parameter List
●
Code: Function / parameter code, written in bx.xx, Cx.xx, Ex.xx, Hx.xx, Ux.xx,
dx.xx
●
Name: Parameter name
●
Default: Factory default
●
Min.: Minimum setting step
●
Attri.: Parameter attribute
– Run: Parameter setting can be modified when the converter is in run or
stop status.
– Stop: Parameter setting can only be modified when the converter is in stop
status.
– Read: Parameter setting is read-only and cannot be modified.
●
DOM: Depends on model
●
[bx.xx], [Cx.xx], [Ex.xx], [Hx.xx], [Ux.xx], [dx.xx]: Function / parameter values
19.3.2 Group b: System Parameters
b0: Basic system parameters
Code
Name
Setting range
Default
Min.
Attri.
Access authority setting
0: Basic parameters
1: Standard parameters
2: Advanced parameters
3: Start-up parameters
4: Modified parameters
0
–
Run
Parameter initialization setting
1: Base device and non fieldbus
options
2: Fieldbus options
3: Base device, non fieldbus
and fieldbus options
1
–
Stop
Parameter initialization
0: Inactive
1: Restore to default settings
2: Clear error record
0
–
Stop
Parameter copy
0: Inactive
1: Backup parameters to panel
2: Restore parameters from
panel
0
–
Stop
EFC x610 Series
Bosch Rexroth AG
Appendix
DOK-RCON03-EFC-X610***-IT05-EN-P
331/389
Содержание EFC 3610 Series
Страница 18: ...Bosch Rexroth AG EFC x610 Series XVI DOK RCON03 EFC X610 IT05 EN P ...
Страница 332: ...Fig 15 15 0020 N 03_0025 N 03 Bosch Rexroth AG Accessories EFC x610 Series 300 389 DOK RCON03 EFC X610 IT05 EN P ...
Страница 333: ...Fig 15 16 0025 A 05 EFC x610 Series Bosch Rexroth AG Accessories DOK RCON03 EFC X610 IT05 EN P 301 389 ...
Страница 336: ...Fig 15 21 0250 N 05 Bosch Rexroth AG Accessories EFC x610 Series 304 389 DOK RCON03 EFC X610 IT05 EN P ...
Страница 421: ...Notes EFC x610 Series Bosch Rexroth AG ...