REXROTH CS 530 Скачать руководство пользователя страница 2

  

 

                                                                  

 

TABLE OF CONTENTS 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 Page 

LAYOUT  ……..............................................................................................................................................2 

2

 

MAIN MENUS  ........................................................................................................................................ 2

 

3

 

AUTHORIZATION VERIFICATION  ........................................................................................................ 3

 

4

 

SYSTEM CONFIGURATION................................................................................................................... 4

 

5

 

GROUND SPEED CALIBRATION .......................................................................................................... 6

 

6

 

HYDRAULIC VALVE CONFIGURATION ................................................................................................ 7

 

7

 

MATERIAL CALIBRATION  ................................................................................................................. 10

 

8

 

DATA SAVING/LOADING/DISPLAYING  ............................................................................................. 12

 

9

 

SUB MENUS  ....................................................................................................................................... 14 

10

 

ERRORS  ............................................................................................................................................. 16 

11

 

UNLOAD  ............................................................................................................................................. 17 

12

 

SPREADING SCREEN  ........................................................................................................................ 17 

13

 

PAUSE/BLAST  .................................................................................................................................... 18 

14

 

UPDATE FIRMWARE  .......................................................................................................................... 18 

15

 

LOGGING REPORT  ............................................................................................................................ 18 

 

 
 
 
 

Bosch Rexroth Canada Corp. reserves the right to revise this information at any time and for any reason and 
reserves the right to make changes at any time, without notice or obligation, to any of the information contained 
in this piece of literature. 

Please check for updates at

www.boschrexroth.ca/compu-spread

 

 
 

Rexroth reserves the right to revise this information at any time, without notice or obligation, to the information in this literature. Please 

check for updates at: 

www.boschrexroth.ca/cs

 

 

Содержание CS 530

Страница 1: ...CS 530 Spreader Controller Configuration Manual...

Страница 2: ...FIRMWARE 18 15 LOGGING REPORT 18 Bosch Rexroth Canada Corp reserves the right to revise this information at any time and for any reason and reserves the right to make changes at any time without notic...

Страница 3: ...ENUS When the truck is stopped or no ground speed signal is coming in the screen below will be shown Power Switch Fuse Power Cable Serial Cable Sensor Cable Valves Cable USB Port Three Encoders with p...

Страница 4: ...0 either a security USB or a password is needed according to the setting of LOCK feature in programming mode This is to prevent unauthorized personnel from making adjustments to the system After press...

Страница 5: ...truck name Press CHG to start to edit the region or truck name Then press FINSH button to quit editing 4 2 Setting the UNIT UNIT To choose the system unit metric or imperial 4 3 Authorization method...

Страница 6: ...als GAT operator is only allowed to change gate setting MAT operator is only allowed to change the material 4 10 Setting the Liquid LIQU to choose liquid either PREWET PRE OR ANTI ICING DEI 4 11 Alarm...

Страница 7: ...ng screen and the text message Run CAL SPD press START will flash Drive the vehicle and hold the vehicles speed as indicated on the speedometer at the value you entered in the CAL SPD field Press the...

Страница 8: ...al Spinner can only work under manual mode Prewet has seven modes off open V Flow slave Return Oil to Pre wet manual speed manual and manual 12V Deice has four modes off manual open and 1 BOOM CONVEYO...

Страница 9: ...the vehicle There are 9 configurable application rate settings available The display will show C on the screen Off This turns off the valves The display will show N beside liquid material V Flow Prewe...

Страница 10: ...um and maximum values can also be accomplished automatically Providing a conveyor sensor is being used in the system Press the ENTER to start the auto null process the text Auto nulling will flash on...

Страница 11: ...E BLAST The first number is the blast rate for blast in closed loop and the next one is the percent of manual blast 7 3 APPLICATION RATES RATE There are 9 settings of the application rate for each mat...

Страница 12: ...the system is safe to run 3 Set the gate position ensure you enter this value in the CAL GATE field 4 Press ENTER to proceed 5 Turn the CONV knob to any position to start the material discharging 6 Pr...

Страница 13: ...the TRIP TOTALS while the SEASON TOTALS can only be cleared in the program setup screen 8 3 Save parameters to USB Press DATA insert program key and follow the hints on screen Once USB FOUND appears p...

Страница 14: ...efreshed to the controller s memory 8 5 Save Controller Logging Data to USB Key When the truck is stopped Press TOTAL first then press DATA insert the log key and press LOG The screen text will show S...

Страница 15: ...Under the simulation mode the system still counts the spreading information into log file so please clear that by resetting the screen totals and retrieving logging data with USB log key 9 2 Gate Adj...

Страница 16: ...te mode is the chosen in the setup screen it will show the AIRGT menu instead of GAT and or MAT Press the AIRGT button to enter the air gate adjustment screen Press the button to switch between low ga...

Страница 17: ...ler power is cycled or the error is resolved Error Messages Suggested Solution Cycle Power Needed BLAST2LONG Turn off blast No DEICE BLST2LONG Turn off blast No OVERSPEED Slow down reset max speed No...

Страница 18: ...neously to exit unload mode Moving the vehicle will suspend the unload process It will automatically resume when the truck is stopped again 12 SPREADING SCREEN When truck is moving system will display...

Страница 19: ...remote blast switch can work together you can turn on blasting using the knob and turn off from the remote blast switch or vice versa For pause mode it can be activated deactivated in parallel either...

Страница 20: ...on When selecting data if the All Data option is selected and no specific truck is selected then all the trucks in that region will be used Further filtered reports can be done by selecting truck name...

Страница 21: ...ll be displayed on the sheet called Report by clicking on Display Truck after choosing the criteria from the above sections For example here you can select region Toroto and truck TUCK03 Click Display...

Страница 22: ...21 15 4 Delete Truck Truck data or region can be erased by clicking Delete Truck A warning message will pop up to confirm the operation...

Страница 23: ......