Features

 

▶ Tightening torque 45 Nm

 

▶ Shock and vibration resistant

 

▶ High resistance to pressure spikes

 

▶ Very good resistance to temperature shock

 

▶ High accuracy over the complete measuring range

 

▶ Compact dimensions for all pressure ranges

 

▶ Thin-film measurement principle

 

▶ Measurement range  

0 ... 280 bar 
0 ... 420 bar and  
0 ... 600 bar

 

▶ Ratiometric output signal 0.5 ... 4.5 V  

at 5 V supply voltage

 

▶ Type of protection IP67 and IP69K

Inhalt

Ordering code 

2

Description 2
Technical data  

3

Characteristics 4
Dimensions 4
Connector Bosch Compact 

5

Manufacturer confirmation of PR4 MTTF

d

-values  

6

Installation instructions 

7

Wiring and error diagnostic of the sensor 

8

Error diagnosis 

9

Safety instructions 

11

Содержание BODAS PR4280GB05/10

Страница 1: ...Compact dimensions for all pressure ranges Thin film measurement principle Measurement range 0 280 bar 0 420 bar and 0 600 bar Ratiometric output signal 0 5 4 5 V at 5 V supply voltage Type of protect...

Страница 2: ...nts Type Material number Bulk pack 136 pieces Single pack PR4 280 G B 05 10 R917C05562 R917A05562 PR4 420 G B 05 10 R917C09842 R917A09842 PR4 600 M B 05 10 R917C10105 R917A10105 Description This senso...

Страница 3: ...perational conditions on request Pressure cycles over service life 10 million cycles Shock resistance 50 g DIN EN 60068 2 27 11 ms 500 g DIN EN 60068 2 27 1 ms Vibration resistance Amplitude of the de...

Страница 4: ...duction line 22 1 Content Digits Count Bosch plant number 23 25 3 Last 4 digits from Bosch part number 26 30 5 Bosch change index 31 32 2 Bosch drawing index 33 35 3 Empty place for CD free sensor 36...

Страница 5: ...e the system Wiring and error diagnostic of the sensor Recommended wiring of the sensor The sensor is to be connected to the ECU according to the following wiring diagram and provided with a supply vo...

Страница 6: ...ately Reset is triggered 2 1 OTP CRC check of boot loading failed 4 times consecutive 2 Sum check on trim data Test carried out during boot loading and continuous cycle 1 error is set immediately Rese...

Страница 7: ...the lower error band In case the error is no longer present the output signal controls its value into the applicable operating range The course of the output signal and the related typical time at roo...

Страница 8: ...time 0 new condition after life time pnenn pnenn 2 Temperature 40 C 1 10 1 50 0 90 1 30 0 70 1 10 0 C 0 70 1 20 0 60 1 10 0 50 1 00 100 C 0 70 1 20 0 60 1 10 0 50 1 00 140 C 1 10 1 50 0 90 1 30 0 70...

Страница 9: ...35 5 Nm Do not exceed the maximum tightening torque of 45 Nm Operating conditions temperatures The sensor is designed for use in hydraulic components direct motor attachment and the corresponding amb...

Страница 10: ...8 365 361 356 347 16h use per day 212 212 211 209 207 203 199 24h use per day 149 148 147 146 145 142 139 MTTFd value of the printed circuit board 15712 11362 8117 5738 4010 2767 1881 Ambient temperat...

Страница 11: ...connector of the sensor is to be unplugged during electrical welding and painting operations Electrostatic painting of the sensor is not allowed hazard ESD damage Cables wires must be sealed individu...

Страница 12: ...certain that the correct pressure measurement device was selected with respect to measurement range design and based on the specific measurement condi tions parts which are in contact with measuring m...