2.0 Instrument at a Glance

 

 
 
 
 
 

 

AudioVine AV 2012B 

Introduction 

 

The AudioVine AV 2012B Sine Oscillator adopts a Phase Shift Oscillator with an improved 
AGC two loop stabilizing system. 
 
Alps pots / switches and Wima caps combined with a high efficiency AGC to meet today’s high-
end development. 
The AV 2012B provides four overlapping bands from 10 Hz to 100 kHz. 
The AudioVine AV 2012B is perfect for: High quality 24 bit ADC tests, Op Amp and Amplifier 
testing, THD / Power measurements, Instrument verification / calibration and by its space saving 
size: perfect for field applications. 
 
The AV 2012B offers two 50 

 unbalanced and 50 

 balanced outputs. 

The Instrument provides a standard 2.5mm DC-IN connector for a standard 12Vdc/1A wall mains 
adapter. 
The AudioVine AV 2012B Oscillator is capable of generating high quality low distortion sine 
wave signals together with a flat noise floor:  
THD+N Ratio ≤ 105dB / 0.0005% @ 1 kHz 4dBu into 600R 
Audio Precision APx555 tested. 
 
-

Please refer to the AV 2012B Datasheet

 

 

 
 

 

 

 

AudioVine – Das Instrument 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание AudioVine AV 2012B

Страница 1: ...Jun 2017 11 1 REV 002_125 REXOTECH Germany AudioVine Low Distortion Sine Generator AV 2012B Manual Rexotech GmbH All Rights Reserved Manufacturer Address Rexotech GmbH Rahmkeweg 41 33758 Schloss Holte...

Страница 2: ...nderungen vorbehalten 2 Free...

Страница 3: ...e of Contents Table of Contents 3 1 0 General Inspection 4 1 1 Symbols In This Manual 4 1 2 Terms 5 1 3 Safety Notices 6 2 0 Instrument at a Glance 7 2 1 Frontpanel 8 2 2 Backpanel 9 EMV EMC Conformit...

Страница 4: ...rrier shall be liable for the damage to the instrument resulting from shipment Rexotech would not be responsible for free maintenance rework or replacement of the unit 1 1 Symbols In This Manual Symbo...

Страница 5: ...or practices that could result in personal injury or loss of life As Marked on Equipment CAUTION indicates a personal injury hazard not immediately accessible as one reads the marking or a hazard to...

Страница 6: ...erve all the Ratings and Symbols on the instrument terminal To avoid fire or shock observe all the ratings and symbols that are marked on the instrument Read the manual carefully before making connect...

Страница 7: ...igh quality 24 bit ADC tests Op Amp and Amplifier testing THD Power measurements Instrument verification calibration and by its space saving size perfect for field applications The AV 2012B offers two...

Страница 8: ...shbutton selects the frequency range By pressing all out the x10k range is selected 5 Frequency tuning Provides a frequency fine tuning of about 1 of the actual setting 6 Output Level Adjustment Sets...

Страница 9: ...ment on or set the Switch 7 to OFF state 2 2 Backpanel 1 DC IN Input for 2 5 mm female wall mains adapter 12 Volt DC 1 0 A Input voltage Range 12Vdc 25Vdc max Attention Use only quality mains adapter...

Страница 10: ...htlinie 89 336 EEC einschlie lich 93 68 EEC und tr gt demgem die CE Kennzeichnung den folgenden europ ischen Produktnormen entspricht EMC NORM Kriterien Einheiten Pr fst rgr en ESD EN 61000 4 2 1995 A...

Страница 11: ...by law Rexotech is not responsible for any faults German Law only No part of this manual may be reproduced without prior agreement and written consent from Rexotech GmbH in Germany and international...