background image

Installation and Maintenance Instructions 

 Falk Steelflex

®

(Page 8 of 9) Type T10 & T20

428-111 

Rexnord Industries, LLC, 5555 S. Moorland Rd., New Berlin, WI 53151-7953

02/2012 

Telephone: 262-796-4060   Fax: 262-796-4064 

Supersedes manuals 428-110, 112, 210 - 04/2005 

e-mail: [email protected]   web: www.rexnord.com

10.2.  Operating limits for Steelflex Couplings

11.  Coupling lubrication

LTG Coupling grease
The High centrifugal forces encountered in couplings separate the base oil and thickener of general purpose greases. Heavy thickener, which 
has no lubrication qualities, accumulates in the grid – groove area of Steelflex couplings resulting in premature hub or grid failure unless 
periodic lubrication cycles are maintained.

Table 6 - Cover fastener tightening torque

Cover Fastener 

Tightening

Size

1020T 1030T 1040T 1050T 1060T

1070T

1080T 1090T 1100T

1110T

1120T

1130T

1140T

T10

lb-in

100

100

100

200

200

200

200

200

312

312

650

650

650

Nm

11.3

11.3

11.3

22.6

22.6

22.6

22.6

22.6

35.0

35.0

73.4

73.4

73.4

T20

lb-in

100

100

100

200

200

200

200

200

260

260

260

650

650

Nm

11.3

11.3

11.3

22.6

22.6

22.6

22.6

22.6

29.4

29.4

29.4

73.4

73.4

Cover 

Fastener 

Tightening

Size

1150T 1160T 1170T 1180T 1190T

1200T

1210T 1220T 1230T

1240T

1250T

1260T

T10

lb-in

650

650

1300

1300

1300

2300

2300

3580

3580

5350

5350

5350

Nm

73.4

73.4

146.9

146.9

146.9

259.9

259.9

404.5

404.5

604.5

604.5

604.5

T20

lb-in

650

1300

1300

Nm

73.4

146.9

146.9

Table 7 - Angular Operation limits

Angular

Size

1020T 1030T 1040T 1050T 1060T

1070T

1080T 1090T 1100T

1110T

1120T

1130T

1140T

X-Y

Inch

0.010

0.012

0.013

0.016

0.018

0.020

0.024

0.028

0.033

0.036

0.040

0.047

0.053

mm

0.25

0.30

0.33

0.41

0.46

0.51

0.61

0.71

0.84

0.91

1.02

1.19

1.35

Angular

Size

1150T 1160T 1170T 1180T 1190T

1200T

1210T 1220T 1230T

1240T

1250T

1260T

X-Y

Inch

0.062

0.070

0.079

0.089

0.097

0.107

0.118

0.129

0.142

0.154

0.169

0.183

mm

1.57

1.79

2.01

2.26

2.46

2.72

3.00

3.28

3.61

3.91

4.29

4.64

Table 8 - Parallel Operation limits

Parallel Offset

Size

1020T 1030T 1040T 1050T 1060T

1070T

1080T 1090T 1100T

1110T

1120T

1130T

1140T

P

Inch

0.012

0.012

0.012

0.016

0.016

0.016

0.016

0.016

0.02

0.02

0.022

0.022

0.022

mm

0.300

0.300

0.300

0.410

0.410

0.410

0.410

0.410

0.510

0.510

0.560

0.560

0.560

Parallel Offset

Size

1150T 1160T 1170T 1180T 1190T

1200T

1210T 1220T 1230T

1240T

1250T

1260T

P

Inch

0.024

0.024

0.024

0.030

0.030

0.030

0.036

0.036

0.038

0.038

0.040

0.040

mm

0.610

0.610

0.610

0.762

0.762

0.762

0.914

0.914

0.965

0.965

1.020

1.020

Type T10

Type T20

Содержание Falk Steelflex T10

Страница 1: ...d shaft 1 2 These instructions are intended to help you to install and maintain your Falk Steelflex coupling Please read these instructions prior to installing the coupling and prior to maintenance of the coupling and connected equipment Keep these instructions near the coupling installationandavailableforreviewbymaintenancepersonnel Forspecialengineeredcouplings Rexnordmayprovideanengineering dra...

Страница 2: ...onforming to ATEX 2 5 All rotating power transmission products are potentially dangerous and can cause serious injury They must be properly guarded in compliancewithOSHA ANSI ATEX Europeanmachinesafetystandardsandotherlocalstandards Itistheresponsibilityof theuserto provide proper guarding 2 6 For ATEX requirements the guard must have a minimum of 12 7 mm 1 2 inch radial clearance to the coupling ...

Страница 3: ...rland Rd New Berlin WI 53151 7953 428 111 Telephone 262 796 4060 Fax 262 796 4064 02 2012 e mail info rexnord com web www rexnord com Supersedes manuals 428 110 112 110 04 2005 3 Components and Part Numbers Figure 2 Falk Steelflex Coupling Components Type T20 Type T10 1020 1140 Type T10 1240 1260 Type T10 1150 1230 ...

Страница 4: ...070T 1080T 1090T 1100T 1110T 1120T 1130T 1140T Seal Kit T10 1 5 0776650 0776651 0776652 0776653 0776654 0776655 0776708 0776709 0707189 0707190 0707191 0707192 0707193 Seal Kit T20 1 5 0706752 0706753 0706754 0706755 0706756 0706757 0706758 0706759 0706760 0706761 0706762 0706763 0706764 Cover Assembly T10 1 2 5 6 7 0775804 0775805 0775806 0775810 0775811 0775812 0776214 0776215 0776216 0776217 07...

Страница 5: ...he distance from the shaft end to the hub face as shown in Figure 3 Record the dimension 7 5 Mount a dial indicator to read axial hub advancement as shown in Figure 4 Alternatively the indicator can be positioned to contact the end of the hub Set the indicator to zero 7 6 Remove the hub and install the key s in the shaft 7 7 Heat the hub in an oven until the bore is sufficiently larger than the sh...

Страница 6: ...d Face Refer to Rexnord bulletin 538 214 Coupling Alignment Fundamentals for instructions regarding shaft alignment 8 1 Close gap coupled couplings Use an inside micrometer or a spacer bar equal in thickness as shown below at 90 intervals to measure the distance between hubs to gap specified in Table 3 8 2 The Angular Misalignment value is the maximum difference between the measurements X and Y ta...

Страница 7: ...cant as possible and wipe off excess flush with top of grid T10 Position seals on hubs to line up with grooves in cover Position gaskets on flange of lower cover half and assemble covers so that the match marks are on the same side If shafts are not level horizontal or coupling is to be used vertically assemble cover halves with the lug and match T20 Slide cover halves with seals onto hubs and pos...

Страница 8: ...ing Size 1150T 1160T 1170T 1180T 1190T 1200T 1210T 1220T 1230T 1240T 1250T 1260T T10 lb in 650 650 1300 1300 1300 2300 2300 3580 3580 5350 5350 5350 Nm 73 4 73 4 146 9 146 9 146 9 259 9 259 9 404 5 404 5 604 5 604 5 604 5 T20 lb in 650 1300 1300 Nm 73 4 146 9 146 9 Table 7 Angular Operation limits Angular Size 1020T 1030T 1040T 1050T 1060T 1070T 1080T 1090T 1100T 1110T 1120T 1130T 1140T X Y Inch 0...

Страница 9: ...lubricant specified on table 9 If coupling leaks grease is exposed to extreme temperatures excessive moisture or experiences frequent reversals or axial movements more frequent lubrication may be required CAUTION Remove grease fitting and make certain all plugs are inserted after lubricating 12 ANNUAL MAINTENANCE 12 1 For extreme or unusual operating conditions check coupling more frequently 12 2 ...

Отзывы: