How To Use This Manual

This manual provides detailed instructions on maintenance, 

lubrication, installation, and parts identification. Use the 

table of  contents below to locate required information.

Table of Contents

Introduction  . . . . . . . . . . . . . . . . . . . . . Page 1

Lube Fittings . . . . . . . . . . . . . . . . . . . . . Page 1

Limited End Float.   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . Page 1

Lubrication .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . Pages 1-2

Installation & Alignment Instructions .   .   .   .   .   .   . Pages 2-4

Annual Maintenance, Relube & Disassembly . . . . Page 4

Installation & Alignment Data  . . . . . . . . . . . . Page 5

Parts Identification & Parts Interchangeability .   .   .   . Page 6

CAREFULLY FOLLOW THE INSTRUCTIONS IN THIS 

MANUAL FOR OPTIMUM PERFORMANCE AND 

TROUBLE FREE SERVICE

.

INTRODUCTION

This manual applies to Sizes 1150T thru 1260T and 150T 

thru 260T Falk SteelfIex Tapered Grid Couplings. Unless 

otherwise stated, information for Sizes 1150T thru 1260T 

applies to Sizes 150T thru 260T respectively, e.g. 1150T = 

150T, 1260T = 260T, etc. These couplings are designed to 

operate in either the horizontal or vertical position without 

modification. 
The performance and life of  the couplings depend largely 

upon how you install and service them. Carefully follow the 

instructions in this manual for optimum performance and 

trouble free service.

CAUTION:

 Consult applicable local and national safety 

codes for proper guarding of  rotating members. Observe 

all safety rules when installing or servicing couplings. 

WARNING:

 Lockout starting switch of  prime mover and 

remove all external loads from drive before installing or 

servicing couplings. 

LUBE FITTINGS

Cover halves have 3/8 NPT Iube holes. Use a standard 

grease gun and Iube fitting as instructed on Page 4.

LIMITED END FLOAT

When electric motors, generators, engines, compressors 

and other machines are fitted with sleeve or straight roller 

bearings, limited axial end float kits are recommended for 

protecting the bearings. Falk Steelflex couplings are easily 

modified to limit end float; refer to Manual 428-820 for 

instructions.

LUBRICATION 

Adequate lubrication is essential for satisfactory 

operation. Page 2 provides a list of  typical lubricants and 

specifications for general purpose and long term greases. 

Because of  its superior lubricating characteristics and 

low centrifuge properties, Falk Long Term Grease (LTG) is 

highly recommended.
The use of  general purpose grease requires re-lubrication 

of  the coupling at least annually. 

Long Term Grease (LTG)

The high centrifugal forces encountered in couplings 

separate the base oil and thickener of  general purpose 

greases. Heavy thickener, which has no lubrication 

qualities, accumulates in the grid-groove area of  Steelflex 

couplings resulting in premature hub or grid failure unless 

periodic lubrication cycles are maintained.
Falk Long Term Grease (LTG) was developed specifically 

for couplings. It resists separation of  the oil and thickener. 

The consistency of  Falk LTG changes with operating 

conditions. As manufactured it is an NLGI #1/2 grade. 

Working of  the lubricant under actual service conditions 

causes it to become semifluid while the grease near 

the seals will set to a heavier grade, helping to prevent 

leakage.
LTG is highly resistant to separation, easily out performing 

all other lubricants tested. The resistance to separation 

allows the lubricant to be used for relatively long periods 

of  time.
Steelflex couplings initially lubricated with LTG will not 

require re-lubrication until the connected equipment 

is stopped for servicing. If  a coupling leaks grease, is 

exposed to extreme temperatures, excessive moisture, or 

experiences frequent reversals, more frequent lubrication 

may be required. 
Although LTG grease is compatible with most other 

coupling greases, the mixing of  greases may dilute the 

benefits of  LTG.

USDA Approval

LTG has the United States Department of  Agriculture Food 

Safety & Inspection Service approval for applications 

where there is no possibility of  contact with edible 

products. (H-2 ratings).

CAUTION:

 Do not use LTG in bearings.

TYPE T10 STEELFLEX COUPLING

Содержание Falk SteelfIex T10 Series

Страница 1: ...loat kits are recommended for protecting the bearings Falk Steelflex couplings are easily modified to limit end float refer to Manual 428 820 for instructions LUBRICATION Adequate lubrication is essential for satisfactory operation Page 2 provides a list of typical lubricants and specifications for general purpose and long term greases Because of its superior lubricating characteristics and low ce...

Страница 2: ...ng Lubricants The values shown are typical and slight variations are permissible DROPPING POINT 300 F 149 C or higher CONSISTENCY NLGI No 2 with 60 stroke worked penetration value in the range of 250 to 300 SEPARATION AND RESISTANCE Low oil separation rate and high resistance to separation from centrifuging LIQUID CONSTITUENT Possess good lubricating properties equivalent to a high quality well re...

Страница 3: ...lace on shafts BEFORE mounting hubs Heat hubs as previously instructed Seal keyways to prevent leakage Mount hubs on their respective shafts so the hub face is flush with the end of its shaft unless otherwise indicated 2 Gap and Angular Alignment Use a spacer bar equal in thickness to the gap specified in Table 1 Page 5 Insert bar as shown above to same depth at 90 intervals and measure clearance ...

Страница 4: ...xtreme or unusual operating conditions check coupling more frequently 1 Check alignment per steps on Page 3 If the maximum operating misalignment limits are exceeded realign the coupling to the recommended installation limits See Table 1 for installation and operating alignment limits 2 Check tightening torques of all fasteners 3 Inspect seal ring and gasket to determine if replacement is required...

Страница 5: ...NMENT END FLOAT TABLE 1 Misalignment and End Float CPLG SIZE Installation Limits Operating Limits Cover Fastener Torque Values Allow Speed rpm Lube Wt Parallel Offset P Angular x y Normal Gap 10 Parallel Offset P Angular x y End Float Physical Limit Min 2 x F Max Inch Max mm Max Inch Max mm Inch mm Max Inch Max mm Max Inch Max mm Inch mm lb in Nm lb kg 1150T 012 305 016 406 250 6 024 610 062 1 57 ...

Страница 6: ...use blue grids Older models 150T thru 260T use orange grids CAUTION Blue grids may be used in all applications but DO NOT substitute orange grids for blue CAUTION DO NOT mix cover halves of different designs WARNING Mixing grid coupling components from different manufacturers may cause premature failure and personal or property damage from flying debris PART NUMBERS 1 Seal T10 2 Cover T10 3 Hub Sp...

Отзывы: