Rexnord Industries, LLC, Coupling Group
458-610
5555 S. Moorland Rd., New Berlin, WI 53151-7953 USA Telephone : 262-796-4060
September 1999 (PDF Revision)
Fax: 262-796-4064 e-mail: [email protected] web: www.rexnord.com
Supersedes 6-82
Falk™ Double & Single Engagement Gear Couplings
•
Install. & Maint.
Type G62 & G66
•
Sizes 1010 thru 1070G
(Page 5 of 6)
TABLE 4 — Installation & Alignment Data For Types G62 & G66
H
— Dimensions – Inches
(Metric – mm)
COUPLING SIZE
1010
1015
1020
1025
1030
1035
1040
1045
1050
1055
1060
1070
Gap
G62
.500
(12,70)
.625
(15,88)
.625
(15,88)
.750
(19,05)
.750
(19,05)
1.000
(25,40)
1.000
(25,40)
1.062
(26,97)
1.312
(33,32)
1.312
(33,32)
1.312
(33,32)
1.375
(34,93)
G66
.536
(13,61)
.656
(16,66)
.656
(16,66)
.748
(19,00)
.748
(19,00)
.968
(24,59)
1.031
(26,19)
1.062
(26,97)
1.344
(34,14)
1.344
(34,14)
1.406
(35,71)
1.500
(38,10)
“X” Dimension
G66
.436
(11,07)
.556
(14,12)
.556
(14,12)
.648
(16,46)
.648
(16,46)
.868
(22,05)
.871
(22,12)
.902
(22,91)
1.144
(29,06)
1.144
(29,06)
1.146
(29,11)
1.170
(29,72)
Installation
Alignment
Limits
Parallel Offset Max
G62
.002
(0,05)
.003
(0,07)
.003
(0,08)
.004
(0,10)
.005
(0,13)
.006
(0,15)
.007
(0,18)
.008
(0,20)
.009
(0,23)
.010
(0,26)
.011
(0,28)
.013
(0,33)
G66
.001
(0,03)
.001
(0,03)
.001
(0,03)
.002
(0,04)
.002
(0,05)
.002
(0,05)
.003
(0,06)
.003
(0,08)
.003
(0,08)
.003
(0,08)
.004
(0,10)
.005
(0,11)
Angular Max
.006
(0,15)
.007
(0,19)
.009
(0,23)
.011
(0,28)
.013
(0,33)
.015
(0,39)
.018
(0,46)
.020
(0,51)
.022
(0,55)
.024
(0,61)
.026
(0,66)
.031
(0,78)
Minimum Speed Range Falk LTG or
NLGl #1 Grease (rpm)
‡
1030
700
550
460
380
330
290
250
230
210
190
160
Grease - pounds
(kg)
G62
.10
(0,045)
.20
(0,091)
.30
(0,136)
.60
(0,272)
.90
(0,408)
1.25
(0,567)
2.00
(0,907)
2.50
(1,13)
4.12
(1,87)
5.12
(2,32)
7.50
(3,40)
9.80
(4,45)
G66
.06
(0,027)
.12
(0,054)
.20
(0,091)
.35
(0,159)
.50
(0,227)
.75
(0,340)
1.20
(0,544)
1.40
(0,635)
2.50
(1,13)
3.00
(1,36)
4.25
(1,93)
5.75
(2,61)
Flange Bolt Torque - lb-in (Nm)
108
(12,2)
372
(42)
900
(102)
1800
(203)
1800
(203)
3000
(339)
3000
(339)
3000
(339)
3000
(339)
3000
(339)
3000
(339)
.3000
(339)
H
Refer to Selection Guide 451-110 for maximum bores and Manual 427-108 for reboring instructions.
‡ Use NLGI #0 grease for speeds up to the minimum shown for NLGI #1 grease.
BI-ANNUAL MAINTENANCE
Re-lubricate coupling if using general purpose grease. If
coupling leaks grease, is exposed to extreme temperatures,
excessive moisture or frequent reversals; frequent lubrication
may be required.
ANNUAL MAINTENANCE
For extreme or unusual operating conditions, check coupling
more frequently.
1.
Check alignment. If the maximum operating misalignment
values are exceeded, realign the coupling to the
recommended installation values. See Table 4, for
installation and maximum operating misalignment values.
2. Check tightening torques of all fasteners.
3. Inspect seal ring and gasket to determine if replacement
is required.
4. Re-lubricate coupling if using general purpose grease.