Operation:

 

1. Make sure the turntable is located on a level surface. Place your stylus pressure gauge

 

on the platter.

2. Press the (POWER) button and wait for the scale to display “0.00”. Wait 10 seconds

to give the gauge’s electronics time to stabilize.

3. The correct downforce for your cartridge is specified in grams. Press the M (Mode)

key until “g” appears in the upper right corner of the display.

4. Gently place the stylus on the scales black dot. When "o” appears on the upper left

the tracking force can be read from the display.

5. Lift the tonearm, adjust the downforce and repeat measurement. Continue process

until the recommended value is attained.

6. Press the button again to turn the scale off.

Calibration: NOTE: Only calibrate if there appears to be a problem with the weight.

 

1. Place the stylus pressure gauge on a level surface.

2.

T

urn on the scale. Wait 10 seconds to give the gauge’s electronics time to stabilize.

3. Wait for the scale to show zero first, then press and hold the power button until the

 

display shows "0"',

then release. Then the required calibration weight will be

 

displayed and blinking.

4. Place the required calibration weight on the scale. After a few minutes, the scale will

stop blinking, the backlight will be brighter, and then the weight will display 

again.

5. Calibration is complete!

Revolv OM-2016