77
Troubleshooting
Operating errors appear as safety codes in the display. If possible, correct the error. If
errors continue, contact REVOLECTRIX Customer Service.
Safety Code/Message
Problem
Increase Supply
NiCd/NiMH charging can’t maintain constant current
Supply <10 Volts
Supply voltage is too low
Supply >32 Volts
Supply voltage is too high
Supply Unstable
Check connections. Increase wire size to charger
Preset no 8Sv2
Preset is meant for a different charger
Bad Preset Version
Preset has a bad version number
NiCd Amps Hi Temp
NiCd/NiMH charging can’t maintain constant current. Reduce charge current
Series Chargers
Check the battery output. Make sure the pack is not in series with another pack.
P. Library Empty
No presets are in the library
Low Voltage Cell
A cell is too low
Preset is Hidden
A hidden preset is trying to run
Reverse Polarity
Check the output pack
Preset is Empty
Preset will not run on charger
ENTR not Pressed
The chemistry has not been confirmed
System Softstart
Check the power supply connections. Check the DPL input current limiting
Preset is Locked
Locked presets can not be changed
Cell No Add Up
Check the node connector and adapters.
Max Cells Error
The unbalanced cell limit has been exceeded
No Pack
A pack has not been detected
Bad Cell Count
Check the node wires and adapter. Check that the proper node wiring
configuration is selected (XH or FMA)
Lost Data Link
Slave charger has an error
Cells Exceeded
The maximum allowed number of cells has been exceeded
Un-Bal Only
The node wire shouldn’t be connected in unbalanced charging
Charge Timeout
The maximum charge time has been exceeded
Cell Cnt Changed
The cell count has changed. Check the pack
NiCd Detected
A NiCd/NiMH pack has been detected in another chemistry
Wrong Cell Count
Check the node wiring and/or selected node type (XH or FMA)
Sply V. down 37%
The supply voltage has dropped too much
Sply < Low Limit
The supply voltage is less than the low limit set point.
Options Corrupt
The options checksum is bad. Factory Restore the charger.
Hi node V.Drop
Node only charging has a high voltage drop. Check the wiring.
Node Over Amps
Check the wiring
1 Primary Only
Check the charger addresses
ERROR ON EXP. CH
One of the slaves has stopped
ERROR ON PRIMARY
The master charger has stopped
Banana Over Amps
Check the wiring for a loose connection. Check the supply wiring too.
WDT System Reset
Check the supply wiring
SVS System Reset
Check the supply wiring