IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

 

www.reversomatic.com • [email protected]     

WARNING

!

!

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY, OBSERVE THE FOLLOWING: 

• This vacuum cleaner is intended for dry pick up only. Do not use on wet surfaces or pick up any liquids, hot
debris or any flammable items that would cause harm to the vacuum cleaner.
• Keep cord away from heated surfaces.
• Use this vacuum only for its intended use as described in this manual. (Use of attachments not
recommended by manufacturer may cause fire, electric shock, injury or damage to system
• components.)
• Connect to a properly grounded outlet only. See ‘Grounding Instructions’ below.
• Mount unit at least 30 cm (12 inches) from the floor, ceiling and corner sidewall to insure adequate
ventilation for motor.
• Never operate this vacuum if it has a damaged cord or plug.
• Never disconnect plug by pulling cord. To disconnect from outlet, grasp the plug, not the cord.
• Do not put any object into openings. Do not use with any opening blocked. Keep free of dust, lint, hair
and anything that may reduce air flow/suction. Lack of air flow will cause the motor to overheat.
• This vacuum cleaner creates suction. Keep hair, face, fingers, all body parts and loose clothing away
from any openings and moving parts.
• Never operate without dust bag and/or filter in place.
• Turn off all controls before unplugging.
• Never handle plug, cord or power unit with wet hands.
• Use extra care when cleaning on stairs.
• Do not pick up anything that is burning or smoking, such as cigarettes, matches or hot ashes.
• Do not use outdoors or on wet surfaces.
• Keep your work area well lit.

.

Do not allow to be used as a toy. Close attention is necessary when used by or near children

• Unplug electrical appliances before vacuuming them.

This vacuum must be grounded (earthed). If it should malfunction or breakdown, grounding (earthing)
provides a path of least resistance for electric current to reduce the risk of electric shock. This vacuum is
equipped with a cord having an equipment-grounding conductor and grounding (earthing) plug. The plug
must be inserted into an appropriate outlet that is properly installed and grounded (earthed) in accordance
with all local codes and ordinances.

                         

 Improper connection of the equipment - grounding conductor can result in a risk of electric shock.

Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded.
Do not modify the plug provided with the appliance. If it will not fit the outlet, have a proper outlet 
installed by a qualified electrician.

GROUNDING INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE

WARNING:

3

2

This appliance is for use on a nominal 120-V circuit and has a grounding attachment plug that looks like the plug
illustrated. Make sure that the appliance is connected to an outlet having the same configuration as the plug.
No adaptor should be used with his appliance.

Содержание RVAC-100

Страница 1: ...ANUAL 790 Rowntree Dairy Road Woodbridge ON Canada L4L 5V3 t 905 851 6701 f 905 851 8376 e info reversomatic com Toll Free 1 800 810 3473 Canada 1 866 890 6457 U S A www reversomatic com RVAC 100 For Household Use Only ...

Страница 2: ...gging Never handle plug cord or power unit with wet hands Use extra care when cleaning on stairs Do not pick up anything that is burning or smoking such as cigarettes matches or hot ashes Do not use outdoors or on wet surfaces Keep your work area well lit Do not allow to be used as a toy Close attention is necessary when used by or near children Unplug electrical appliances before vacuuming them T...

Страница 3: ...Parts List 4 1 2 Latch 3 Pre filter 4 Dust Bag 5 Spider Gasket Set 6 Control Board PCB 7 Motor 9319 Reference Description Part Number 012994 012995 012996 012997 012998 012999 Vacuum Cleaner Body ...

Страница 4: ... VALVE WHITE VF 791041 W CASE HAYDEN MOUNTUNG PLATE 2 X 4 STUD WHITE VF PVC 2 8 WHT 211 VACUUM PIPE SOFT BUNDLE WHITE ASTM STANDARDS VF VG 10362 VACUBOND GLUE 12SML CLEAR VK SAK 138 30 STANDARD AIR KIT WITH 30 LOW VOLTAGE HOSE ON OFF SWITHC LT GREY VK SAK 138 35 STANDARD AIR KIT WITH 35 LOW VOLTAGE HOSE ON OFF SWITHC LT GREY RVAC 100 VACUUM CLEANER LT 400V LINT TRAP COMPLETE 4 X 4 OR 4 X 5 PAINTED...

Страница 5: ...hould be mounted about 48 122 cm up from the floor to allow convenient removal of the bottom for maintenance For proper motor cooling there must be at least 12 31 cm between unit and the ceiling If mounting on plaster or panel walls be sure mounting screws enter studs If mounting on concrete wall drill the wall with a masonry bit and insert the appropriate wall anchors Do not exceed a run of over 2...

Страница 6: ...tection shut off to protect the power unit from overheating Please allow for the unit to cool for approximately 30 minutes If the unit does not restart after the 30 minutes please contact your local authorized dealer distributor 2 Partial Loss of Suction i Clean out dirt receptacle Ensure filter is free from debris tears and or punctures If this does not resolves issue see step 2 ii Turn ON vacuum ...

Страница 7: ...f Wall Box Option 1 Suction Port Dryer Washer Vacuum Cleaner Clamp Booster Fan TLD INSULATION Minimum 5 Feet 1 Thick 5 ft Leak Proof Wall Box INSULATION 5 ft Booster Fan TLD Leak Proof Wall Box Minimum 5 Feet 1 Thick Option 2 INSULATION 5 ft Booster Fan TLD Minimum 5 Feet 1 Thick Vacuum Cleaner Suction Port Dryer Washer INSULATION 5 ft Leak Proof Wall Box Minimum 5 Feet 1 Thick Wall Suction Port G...

Страница 8: ...Notes 12 ...

Страница 9: ... 2018 790 Rowntree Dairy Road Woodbridge ON Canada L4L 5V3 Tel 905 851 6701 Fax 905 851 8376 info reversomatic com Toll Free 1 800 810 3473 Canada 1 800 499 5073 U S A w w w r e v e r s o m a t i c c o m Notes 13 ...

Отзывы: