Fan-coil Unit

HRV/ERV

HRV and ERV Typical Installations

4

2 Single Vents 

SVE-50 and SVI-50

Shown.

“Fresh Air/ ExhaustAir  

Vents Installation”

HRV/ERV (SUPERIOR)

HRV/ERV

RETURN-AIR DUCT

FURNACE

Semi Ducted System

Double Vent with Extruded Aluminum Grille

DVG200 shown “Fresh Air/Exhaust Air Vent installation”

from washrooms  

and kitchen

• This installation enables stale air to be drawn from the

poorest air quality areas of the home (washrooms & kitchen)

Note:

• It is recommended that the furnace blower run continuously or HRV/ERV operation be interlocked with the furnace blower

to evenly distribute the fresh air throughout the house.

• A backdraft damper is required in the exhaust air duct to prevent outdoor air from entering the unit when the Furnace /

Air handler is running and the unit is in Standby, OFF or in Recirculation.

Installation Options for High-Rise Condominium

Fully Ducted

System

System

FRESH AIR 

EXHAUSTEDAIR

Typical Installations for House

Fully Ducted System

This is a stand alone HRV/ERV system which is not 

connected to a force air system. Stale air is drawn from 

key areas of the home (bathroom, kitchen) while fresh 

air is supplied to main living areas.

Furnace Return Air-duct Connection

DVS100

Double Vent with hood shown “Fresh Air/Exhaust Air Vent installation”

Abovethe  

Snowline

Note:

All Exhaust Vents must be installed

min. 5 ft away from sidewalls

.

Note:

All HRV / ERV must be balanced in the field.

Fan-coilUnit

HRV/ERV

Distance  

“X”

Wall Cap 

Exhaust/Intake  

WCE-5,WCI-5

shown

*Re - Circulation Efficiency

If distance “X” is 5ft - 99.7%

“X” is 3ft - 96.5%

With Fan-Coil

•Fresh air from outside should be installed on

Fan-coil supply side (HRV/ERV station #2) 

and HRV/ERV should be interlocked with 

Fan-coil unit.

BalancingBox  

(recommendedair filter for  

autobalancingunit to prevent

dustbuild-upon air flow sensors)

Содержание RERV-C100ECM

Страница 1: ...Canada L4L 5V3 Tel 905 851 6701 Fax 905 851 8376 www reversomatic com info reversomatic com US CERTIFIED C New HRV ERV INSTALLATION AND OPERATION INSTRUCTIONS Field Balancing Ports RHRV C100PECM Polypropylene Core RERV C100ECM Enthalpy Core ...

Страница 2: ...llation servicing or cleaning these unit it is suggested to wear safety glasses and gloves 9 Do not use this unit for commercial purpose 10 For residential use only The unit must be grounded 11 Do not install in a cooking area 12 This unit is not designed to exhaust combustion and or dilution air for fuel burning appliances CAUTION 1 Turn the unit OFF during construction or repair to avoid filter b...

Страница 3: ...rol Board Superior ECM 9361 ECM 1 1 14 Main Control Board Bracket 9355 2 2 15 Door Hinges 9328 1 Set 1 Set 16 Mounting Brackets 011135 4 4 17 T Connector 9330 1 1 18 Webbing Brackets Ladder Locks 9332 2 Sets 2 Sets 19 Chains Springs Brackets 9354 1 Set 1 Set 20 Drain Pipe 9331 1 1 21 Motorized damper spring return 120V 9362 1 1 22 Motorized Damper Spring return Built in by Factory 9363 1 1 Parts L...

Страница 4: ...5 DAT GND YEL RED GRN YEL RED GRN TC100 5V YEL RED GRN Intermittent OR Timer Switch 1 FAN Exhaust FAN Supply AC connection Door Safety switch Temp Sensor Exhaust FAN motor f HRV ERV Hi Low 120 Vac 1 60Hz Power Supply Light Switch Option b Light On Off Remote 0n 0ff HV Jumper remove jumper to install master ON OFF switch Ext Interlock OR Ground DC connection Note Make sure the Line must be connected ...

Страница 5: ...HERMOSTAT TERMINALS W R G Y TWOWIRE W A R N I NG Never connect a 120 volt AC circuit to the terminals of the furnace fan coil heat pump interlock Standard Wiring Only use the low voltage class 2 circuit Note These Connections must be done inside the electricalbox NO C NC These connections must be done inside the electrical box FOUR WIRE GND DAT 5V SUPERIOR ECM CONTROLBOARD W R G Y C TWOWIRE heatin...

Страница 6: ...r in Recirculation Installation Options for High Rise Condominium Fully Ducted System System FRESH AIR EXHAUSTEDAIR Typical Installations for House Fully Ducted System This is a stand alone HRV ERV system which is not connected to a force air system Stale air is drawn from key areas of the home bathroom kitchen while fresh air is supplied to main living areas Furnace Return Air duct Connection DVS...

Страница 7: ...e person installation for vertical and horizontal installation VERTICAL Note After installation make sure the HRV ERV is properly leveled If not levelled correctly then defrost will not perform effectively and or unit may frost in winter UP UP PULL DOWN Strap NOTSUPPLIED j tantay 12 23 11 Vibration Spring Washer Screw CHAIN MOUNTING SYSTEM optional Available for both horizontal vertical installati...

Страница 8: ...e this drain for horizontal installation Note For Horizontal installation connect only 1 drain spout assembly on lid door cut one drain pipe and connect one end to the drain spout and the other end to the drain line Don t forget to create a P trap as shown above HRV must be connected to drain ERV does not required any drain However we recommend to connect ERV to drain in areas where extreme cold w...

Страница 9: ...from the other duct The flows should now be balanced Actual airflow can be determined from the gauge metre reading The value read on the gauge is called the velocity pressure and on the flow meter is called air velocity FPM The Pitot tube comes with a chart that will give the air flow velocity based on the velocity pressure indicated by the gauge This velocity will be in either feet per minute or metr...

Страница 10: ...slide it to the left 3 Clean the inside of the door and drain pan with a damp cloth to remove dirt and debris that may be present 4 Clean the filters twice a year Remove the filters Vacuum to remove most of the dust Wash with a mixture of warm water and mild soap Rinse thoroughly and shakefilters to remove water and let dry 5 Oil grease defrost damper levers and hinges 6 Check air flow sensors twice a...

Страница 11: ...he fan motor wires remove the screws securing fan assembly pull the fan assembly out of unit check for any accumulation on the blades clean with a small brush if necessary scrub individual fan blades until clean vacuum and wipe put the components back in place reconnect the power supply and turn the unit back on PROBLEMS POSSIBLE CAUSES SOLUTION 1 Air flow is low HRV ERV airflow improperly balanced ...

Страница 12: ...and the remote wall mount Timer Switch will flash 0 5 sec On 0 5 sec Off 0 5 sec On then 2 sec Off then repeat the cycle Exhaust fan open circuit a motor burned b fan overheated replace motor call technician if possible replace fan damper obstructed exhaust fan jam over current check backdraft damper no screw must interfere the function of the damper replace the fan 8 LED s on the Main Control boa...

Отзывы: