13.
LIGHTING AND RELIGHTING INSTRUCTIONS
(Robertshaw Control)
IMPORTANT: GAS COCK KNOB CANNOT BE TURNED FROM "PILOT" TO
"OFF" UNLESS THE KNOB IS PARTIALLY DEPRESSED.
1 Turn OFF burner "ON / OFF" switch (mounted on the wall).
2 Turn gas control knob so indicator points to "OFF" position and allow 5 minutes for any
gas in the combustion chamber to escape.
3 Turn gas control knob counterclockwise so indicator points to the "PILOT" position
Depress fully the gas control knob and while continuing to hold the knob down, push the
ignitor button several times, or until the pilot lights.
After approximately 1(one) minute, release the gas control knob The pilot flame should
remain lit. If it does not remain lit, repeat this operation and allow a longer period before
releasing the gas control knob.
4 When the pilot has been ignited, turn the gas control knob further counterclockwise to
the "ON" position
5 Turn the "ON / OFF" switch to "ON" and the burner should ignite
NOTE If the burner does not ignite and the pilot is still lit, turn the gas control knob to
"OFF" and call a qualified service representative.
SHUT DOWN INSTRUCTIONS
1 Turn wall on / off switch to "
OFF
"
(or turn down thermostat if one is used)
2 Turn the gas control knob to the "
OFF
" position.