Domestic axial fan with throttle
VELO and VELO Silver series
User Manual
Introduction
Thank you for choosing our product. Reading of this manual
is required for proper use of the device and absolute
observance to its guidelines is fundamental condition
of security.
All users of the device should have free access
to the manual and in case of resale, the instruction must
be attached to the product.
Package contents
- domestic axial fan VELO
- user manual
Transport and storage
The fan should be transported and stored in the original
packaging in a dry place protected from contamination,
until it is installed. Moreover, the fan should be protected
from the shocks.
Application
Axial fans from the VELO series are designed for wall
mounting. They are used for ventilation of small spaces
such as a bathroom or kitchen.
The device comes in two colors - white or silver (VELO Silver
version).
Construction of the device
1
–
Panel
2
–
Sensor 3
–
Casing
4
–
Motor
5
–
Rotor
,w
6
–
Throttle frame
7
–
Throttle
8
–
Fastening ring 9 - Frame
Dimensions (in mm)
MODEL
ØA
B
C
D
VELO 100 & VELO SILVER 100
100
150
90
35
VELO 150 & VELO SILVER 150
150
193
100
35
Technical data
MODEL
VELO 100 &
VELO Silver 100
VELO 150 &
VELO Silver 150
Maximum aiflow [m
3
/h]
95
240
Maximum compression [Pa]
36
60
Voltage [V] / Frequency [Hz]
230 / 50 - 60
230 / 50 - 60
Rated current [A]
0.072
0.138
Engine speed [rpm]
2400
2000
Engine power [W]
12
18
IP protection degree [-]
X4
X4
Noise [dB(A)]
34
35
Installation instructions
In order to accomplish the installation of the device
successfully and enable the safe usage of the fan
in the future, it is essential to follow the instructions in this
manual.
Before installing and connecting the fan, check that it has
not been damaged during transport or storage (breakage,
distortion).
Check whether the technical data on the nameplate
corresponds to the electrical installation parameters.
The device should be mounted on a flat surface.
If irregularities are not found, you can proceed
with the installation as follows:
- prepare appropriate electrical wires
- mark the location of mounting holes
- drill the holes and put expansion bolts in them
- place the fan in the right place and tighten screw it
- connect the device to electrical grid
The electrical connection must be in accordance
with the wiring diagram in the terminal box.
Warnings and precautions
During the operation of the device, the following
precautions must be observed:
- before performing any work, the device must
be disconnected from the power supply
- the fan is intended only for ventilation of rooms with small
and medium cubature
- if you do not use it for a long time, it is recommended
to disconnect the device from the power supply