1. INTRODUCTION

Thank  you  for  purchasing  air  curtain  AERIS.  We  would  like  to  congratulate 
on good choice. Please read and save these instructions.

1.1 PRECAUTIONS

The  buyer  and  the  user  of  the  device  should  read  carefully  the  following 
instructions  and  proceed  to  the  content  recommendations.  Proceeding 
due to the following instruction guarantees the correct usage and safety. In case 
of  any  doubts  please  contact  Reventon  Group  sp.  z  o.  o.  [Ltd.].  The 

s

upplier 

reserves  the  rights  to  make  changes  to  the  technical  documentation  without 
previous  notice.  Reventon  Group  sp.  z  o.  o.  [Ltd.]  is  not  responsible 
for the damages which occur due

 

to improper installation, not keeping the device 

in  repair  or  using  the  device  out  of  line.  The  installation  should  be  carried 
out  by  the  professional  installers,  who  possess  the  qualifications  to  install 
these

 

types of devices. The installers are responsible for making the installation 

as  instructed  in  the  technical  data.  Regulations  and  safety  rules 
must be followed. During the installation, use, service and periodical inspections 
all regulations and safety rules must be followed. In case of unserviceable please 
plug  out  the  device  and  contact

 

with  the  authorized  person  or  the 

s

upplier. 

All  safety  requirements  must  be  taken  into  account  during  installation, 
use or inspection. 

1.2 TRANSPORT

During  the  acceptance  of  goods  it  is  needed  to  check  the  device  in  order 
to  exclude  any  damages.  During  the  transport  it  is  needed  to  use  the  proper 
equipment,  it  is  necessary  to  carry  the  device  by  two  people.  In  case 
of  any  damages  please  fill  in  the  damage  report  in  presence  of  the 

s

upplier 

or the carrier.

1.3 

PACKAGE CONTENT

unheated air curtain

operation and maintenance manual and warranty card

assembly panel

door sensor

- remote controller

1.4 

USE

Unheated  air  curtains  (without  heat  exchanger)

  are  widely  installed 

at  the  entrances  of  supermarkets,  theaters,  meeting  rooms,  hotels,  offices, 
storages  etc.  They  can  reduce  penetration  of  insects,  outside  dust, 
unconditioned  air  into  a  conditioned  space  by  forcing  an  air  stream  over 
the entire entrance. In winter they prevent uncontrolled heat loss and in summer 
they  prevent  heat  from  the  room.  However,  air  curtains  should  not  be  used
in corrosive environments for aluminum, copper and steel as well as in highly 
dusty environments (above 0.3 g/m   ).The devices should also not be installed 
in  rooms  where  they  would  be  exposed  to  high  humidity  or  direct  contact 
with water.  

 ENG

 

     

 

T ECHNICAL DATA

3

2.2 TECHNICAL DATA

MODEL

REVENTON GROUP

AERIS 100C-1P

REVENTON GROUP

AERIS 150C-1P

REVENTON GROUP

AERIS 200C-1P

1000

1500

2000

132

90

18.0

25.0

G

N.W (KG)

13.5

440

---

---

---

---

330

330

247

218

H

440

660

AERIS 100C-1P

AERIS 150C-1P

AERIS 200C-1P

1770

3150

3540

1450

2550

2900

11

11

11

9

9

9

230/50

230/50

230/50

180

230

360

130

180

260

13.5

18.0

25.0

56

57

58

54

55

56

E / IP 20

E / IP 20

E / IP 20

0.78

1.00

1.57

0.57

0.78

1.13

3

3

3

II STAGE

I STAGE

II STAGE

I STAGE

II STAGE

II STAGE

I STAGE

II STAGE

I STAGE

II STAGE

I STAGE

TECHNICAL DATA 

Product code

Maximum 
airflow [m /h]

Maximum air speed
[m/s]

3

Curtain’s range [m]

Supply

 voltage [V] /

 Supply

 frequency [Hz]

Motor power [W]

Rated motor 
current [A]

Class of isolation / Protection degree IP [-]

Net weight [kg]

Noise [dB]

AC100C1P