Electrical  •  21

General

Standard cases have 2 electrical circuits: the fan circuit and the lighting circuit (

See Figure 40

). 

Always refer to the wiring diagram shipped 

with the case.

The case light switch is located on the right side of the interior ceiling (

See Figure 41

).

The electrical enclosure is located behind the lower trim on the right side of the case (

See 

Figure 42

). The electrical raceway allows for simple case-to-case wiring (

See Figure 43

). 

power can be supplied to the case through the access hole under the electrical enclosure 

(

See Figure 44

). The enclosure includes the power connection and power supplies for the 

LED light bars. Terminal blocks are provided for supplying power for fans and lights. A ground 

connection can also be made inside the electrical enclosure.

Optional top electrical will be located in a junction box on top of the case.

The factory-installed temperature probe (discharge air) is located in the false ceiling. 

Temperature probe wires are white (common) and green (supply). 

ELECTRICAL

 FIGURE 41: Light Switch

 FIGURE 40: Sample Wiring Diagram

RELEASED

65-1433

LABEL  W/D MAIN LOWER  TRAY

MP

ZERO ZONE, INC.

TYPE II PAPER LABEL (PER ES-08-1007-154)
NONE

01/11/21

1 OF 1

04

04 Change from NEUT 52 (TB 5) to NEUT 42 (TB 4)

and NEUT 102 (TB 10) to NEUT 52 (TB 5)

4166

10/18/2021 OP

65-1433

LABEL W/D MAIN LOWER TRAY

P

4.

75 

± 

0.

1

10.0 ± 0.1

NOTE: 

USE LABEL-ONLY FILE FOR PRINTING - DO NOT USE LABEL ART FROM THIS DRAWING.

WIRE NO.

FROM

TO

COLOR

0

STORE OR UPPER

GND STUD

GRN

7

TB  N3 (UPPER)

32  (TB 3)

WHT/R-P-O

8

TB  N2 (UPPER)

22  (TB 2)

WHT/BLU

9

TB  N1 (UPPER)

12  (TB 1)

WHT/ORG

10

TB  L3 (UPPER)

D2  (TB D)

BLK/R-P-O

11

TB  L2 (UPPER)

C2  (TB C)

BLU

12

TB  L1 (UPPER)

B2  (TB B)

ORG

17

E1  (TB E)

LED DRIVER LINE

BLK or ORG

18

31  (TB 3)

ANTI-SWEAT NEUT

WHT/BLU

19

21  (TB 2)

FANS NEUT

BLU (RIBBED)

20

71  (TB 7)

LED DRIVER NEUT

WHT OR WHT/ORG

21

D1  (TB D)

ANTI-SWEAT LINE

BLU

22

C1  (TB C)

FANS LINE

BLU (SMOOTH)

23

B1  (TB B)

LIGHTS  SWITCH

ORG

24

A1  (TB A)

LIGHTS  SWITCH

ORG

J1

A2 (TB A)

E2 (TB E)

BLK

J2

11 (TB 1)

61 (TB 6)

WHT

NOTES:

TB E  AND TB F RESERVED FOR LED AC LINE CONNECTIONS

TB 6  AND TB 7 RESERVED FOR LED AC NEUTRAL CONNECTIONS

ALL REMAINING UNRESERVED TERMINAL BLOCKS ARE SPARES

20

USE COPPER CONDUCTORS

11

12

9

0

(CUSTOMER CONNECTIONS OR WIRING FROM UPPER BOX)

FANS (115V)

LIGHTS (115V)

GROUND

LOWER ELECTRICAL TRAY

ANTI-

SWEAT

23

18

21

A/S (115V)

10

FANS (NEUT)

LIGHTS (NEUT)

A/S (NEUT)

LIGHTS

SWITCH

FANS

19

22

23

24

WIRE 22 = SMOOTH-INSULATION FAN WIRE

WIRE 19 = RIBBED-INSULATION FAN WIRE

115VAC RCPT - PWR BY CUST

LINE G2 (TB G), NEUT 42 (TB 4)

SOLENOID VALVE

LINE H2 (TB H), NEUT 52 (TB 5)

M

P/N 65-1433  REV P

W/D MAIN LOWER TRAY

ZERO-ZONE.COM

800 247 4496

LED POWER

& DIMMING

(SEE AUX DIAGRAM)

J1

J2

C2

22 32

C1

21 31 41 51

42 52

B2

B1

61

62

A2

A1

D2

D1

E2 F2

H2 12

E1 F1

H1 11

G2

G1

72

71 81 91

82 92

101

102

SAMPLE

 FIGURE 42: Bottom Electrical Enclosure

 FIGURE 43: Case-to-Case Wiring

 FIGURE 44: Electrical Supply Access Hole

Содержание ZERO ZONE

Страница 1: ...ZERO ZONE REVEAL MERCHANDISER OPEN MULTI DECKS With ChillBrite LED Lighting INSTALLATION OPERATION MANUAL COMPLIANT 66 0057 REV F Apr 2022...

Страница 2: ...13 Bumper 13 Mirrors 14 Night Curtains 15 Under Shelf Lights 15 Canopy Lights 16 Quick Connect Spray Hose 16 Shelves Stocking Product 17 REFRIGERATION 18 Mechanical Components 18 Evaporator Coil Expa...

Страница 3: ...all not be covered by this warranty Extended Warranties In addition to the standard limited warranty for further consideration the Seller will extend to the original purchaser prior to shipment a limi...

Страница 4: ...questions or problems arise call Zero Zone at 800 247 4496 Any change to a Zero Zone product made during the installation start up or at any other time must be submitted in writing to Zero Zone for ap...

Страница 5: ...ezers ANSI Approved equipment certified by NSF NSF 51 Food Equipment Materials ANSI Approved equipment certified by NSF UL 471 Commercial Refrigerators and Freezers ANSI Approved equipment certified b...

Страница 6: ...nd the second case in the lineup will be labeled on the left end The numbers on each end to be joined will match See Figure 1 The first case in a lineup with the right side labeled x 1 has a packet at...

Страница 7: ...ns CASE MODEL INSTRUCTIONS 4ORMC Forks must extend 20 to 24 under the case from either end 6ORMC Forks must extend 26 to 30 under the case from either end 8ORMC Forks must extend 39 to 43 under the ca...

Страница 8: ...not extend beyond the front case bases or they will interfere with installing trim The shims should be oriented to sit under the front and rear bends of each base Tape all shims in place See Figure 7...

Страница 9: ...ration Figure 8 Reveal Merchandiser Base Locations 4ORMC 6ORMC 8ORMC 12ORMC Drawings are top views with bases shown under the case The front of the case is toward the bottom of the page Case length do...

Страница 10: ...k before setting the next case in the lineup Case caulking instructions and caulk are shipped with every case See Figure 10 on page 9 Move the next case into position and bolt it to the first case usi...

Страница 11: ...IS CRITICAL TO FOLLOW THIS PROCEDURE TO ENSURE CASES ARE PROPERLY SEALED SURFACES TO BE CAULKED MUST BE CLEAN DRY FREE OF TAPE ADHESIVE AND FREE OF FROST ABOVE 40 F Note Apply Butyl caulk to only one...

Страница 12: ...aling Wipe away any Butyl caulk that squeezes out of the case joint Butyl caulk and silicone sealant will not mix which affects the adhesion of both See Figure 10 on page 9 1 Apply silicone based seal...

Страница 13: ...to loosen the canopy screws if canopies are not within 3 8 On cases with angled sheet metal canopies the splice is shipped loose Fit it over both canopies and screw into place Hand Rail Splice Some c...

Страница 14: ...se in the center The lateral runs of drain pipe should be installed through the bases See Figure 18 There is no room in front of the base for the drain pipe because the kickplate installs directly to...

Страница 15: ...If a continuous bumper is used only the bumper support and snap track will be installed The continuous bumper may need to be trimmed before snapping it onto the snap track Figure 19 Kickplate Installa...

Страница 16: ...Install Mirror Support into the Shelf Standards Install into second and third slots from the top Figure 22 Shelf Standard Slots for Air Deflector MIRROR HEIGHT SLOT FOR AIR DEFLECTOR 8 Tall 6th Slot f...

Страница 17: ...st it until you hear a click as the brackets engage See Figure 25 Once installed the night curtain can be pulled down See Figure 26 Under Shelf Lights 1 Position the under shelf light on the bottom of...

Страница 18: ...O T C E N N O C E L A M E F 8 3 0 0 4 6 7 6 4 D E V L A V L E E T S S S E L N I A T S 0 0 0 8 1 F E R 7 4 5 S E T O N E V A H O T E R A S T R A P R O T C E N N O C 1 N O I T A M R O F N I T H G I R Y...

Страница 19: ...rack Note Do not place product on the return air grille or past the load limit line Do not exceed shelf load capacity See Figure 34 Do not stand on the case when stocking or adjusting shelves Shelves...

Страница 20: ...ature range wattage and RPM Fan blades should be replaced with OEM parts or have the same fan pitch as the OEM fan blade CAUTION DISCONNECT POWER TO THE CASE BEFORE SERVICING ELECTRICAL COMPONENTS TO...

Страница 21: ...st See Figure 39 for off cycle defrost settings During off cycle defrost refrigerant is stopped either by stopping the compressor or by closing the liquid line solenoid valve and allowing the compress...

Страница 22: ...ter is factory mounted in the center ceiling pocket cover to sense the discharge air stream The second thermometer is shipped loose and should be installed in the warmest product location as required...

Страница 23: ...Y FILE FOR PRINTING DO NOT USE LABEL ART FROM THIS DRAWING WIRE NO FROM TO COLOR 0 STORE OR UPPER GND STUD GRN 7 TB N3 UPPER 32 TB 3 WHT R P O 8 TB N2 UPPER 22 TB 2 WHT BLU 9 TB N1 UPPER 12 TB 1 WHT O...

Страница 24: ...a mild detergent and warm water or a mild sanitizer 6 If the case is equipped with a condensate pan and pump the drain should be blocked before washing coils Water can be removed with a shop vacuum 7...

Страница 25: ...cal Resources page at WWW ZERO ZONE COM or contact the Zero Zone Service Department at 800 247 4496 All specifications subject to change without notice 66 0057 REV F ZERO ZONE INC 800 247 4496 ZERO ZO...

Отзывы: