waterproof))
Figure 1
Figure 2
Figure 3
• It not only can install on the wall directly but also can install on the inner corner with the help of the widget (refer
to the photograph below).
Flat mounted
Inner corner mounted
CONNECTION-WIRE DIAGRAM
See the right figure
TEST
• Turn the TIME knob anti-clockwise on the minimum (10s). Turn the LUX knob clockwise on the maximum (sun)
• Switch on the power; the sensor and its connected lamp will have no signal at the beginning. After Warm-up
30sec, the sensor can start work .If the sensor receives the induction signal, the lamp will turn on. While there is
no another induction signal any more, the load should stop working within 10sec±3sec and the lamp would turn
off.
• Turn LUX knob anti-clockwise on the minimum (3). If the ambient light is more than 3LUX, the sensor would not
work and the lamp stop working too. If the ambient light is less than 3LUX (darkness), the sensor would work.
Under no induction signal condition, the sensor should stop working within 10sec±3sec.
Note: when testing in daylight, please turn LUX knob to
(SUN) position, otherwise the sensor lamp
could not work! If the lamp is more than 60W, the distance between lamp and sensor should be 60cm at
least.!
SOME PROBLEM AND SOLVED WAY
• The load does not work:
a. Please check if the connection of power source and load is correct.
b. Please check if the load is good.
c. Please check if the settings of working light correspond to ambient light.
• The sensitivity is poor:
ANL_28502 1.indd 6
2016/2/22 16:40:16