SuperCleanox Operating instructions
Page
35
of 62
Click
Earth clip connection
The earth clip (3) establishes the electrical contact between the
workpiece and the electrochemical cleaning appliance.
Very high currents flow during cleaning.
Connect the earth clip directly to the workpiece to be cleaned,
to prevent shunts.
Ensure good electrical contact between the earth clip (3) and the
workpiece.
Clean the contact point if necessary.
Connect the
red
high-current plug (1) to the
red
combo jack (2) on the
appliance.
15.2 Connect and lock the high-current plugs
Note
The high-current plugs lock automatically when inserted into the high-
current combo jacks and can only be unlocked by pressing inwards again!
Ensure that the connections are correct.
Red high-current plug in red high-current jack.
Black high-current plug in black high-current jack.
The following procedure applies for
red
and
black
high-current
plugs.
Push the high-current plug into the high-current combo jack
until you feel a distinct clicking.
Check the correct fitting of the high-current plug by pulling
it gently.
The plug should not pull out.
15.3 Release high-current plug and remove
To release, press the high-current plug lightly into the high-
current combo jack until you feel resistance (slight click).
The lock is released.
Now pull the high-current plug out of the high-
current combo jack.
15.4 Connecting the marking / cleaning stamp
Insert the
black
safety plug (2) with the transparent, sliding, insulating
sleeve into the jack in the handle (1).
Insert the
black
10mm² high-current plug (6) into the
black
high-current
combo jack (8) on the appliance
Cleaning stamp
1
2
3
4
Marking stamp
1 Handle
2 Safety plug
3 High-current plug
4 High-current jack (front of appliance)
Click
Workpiece
Ensure sufficient
contact!
1 High-current plug "
red
“
2 High-current jack "
red
"
3 Earth clip
1
3
2