SuperCleanox Operating instructions
Page
27
of 62
14.2 Earth clip with cable and plug
Safety information
Earth connections are always "
red
".
The earth clip (1) is fixed to:
Red 10/16mm² cable (2)
Red high-current plug (3).
Always insert the red high-current
plug (3) into the red combo jack (4).
The earth clip (cast brass clip)
establishes the electrical contact between
the workpiece and the electrochemical
cleaning appliance.
Very high currents flow during
cleaning. Connect the earth clip
directly to the workpiece to be cleaned,
in order to avoid shunts.
Ensure bare metal contact points.
14.3 Carbon fibre brush XL
Use the carbon fibre brush supplied, type XL, for
cleaning welds.
The carbon fibre brush comprises the following
components:
≈ 1.5 million individual carbon fibres (1)
The light arcs, important for the cleaning
process, form on the ends of these fibres
Connection piece with internal thread (3)
Fixing the brush on Teflon handle and
power transmission: Handle <--> carbon
fibre
Teflon sliding sheath
Wear compensation
The combustion of the carbon fibres is
compensated for by sliding
See our accessories catalogue for a variety of
special sheaths for different applications, available
in addition to the carbon fibre brush supplied.
Note
New brushes must first be worked in before they develop their full
cleaning effect.
You can speed up the burn-in process by working at level II on a
piece of scrap sheet for a few seconds in advance.
1
2
3
4
1 Earth clip
2 Cable 10/16mm² "
red
"
3 Insulated high-current plug "
red
"
4 High-current jack "
red
"
1 Carbon fibres
2 Teflon sliding sheath
3 Threaded piece
4 Insulating sleeve
2
1
4
Wear compensation
3