1.  This fountain is to be mounted on a smooth, flat, finished surface with adequate support structure. NOTE: Mounting structure  

     must be capable of supporting 300 lb. load on fountain.

2.  Refer to rough-in for plumbing.

3.  Install shut-off valve on water supply. (Valve not furnished)

4.  Locate and install fountain using 3/8" minimum fasteners. (Fasteners not furnished)

5.  Prior to installing the bottle filler to the center mounting position of fountain, insert the drain pipe (Item #15)  by positioning the 

     short end of drain pipe through mounting plate of  bottle filler.  Install bottle filler to fountain and secure with supplied hardware.

6.  Prior to installing the bottle filler to the arm mount of fountain, insert the drain pipe (Item #14) into the arm tunnel and adjust 

     drain to lean to the left side of the arm when facing the button.  Install bottle filler to arm being sure drain tube is above 

     mounting plate of filler. Install filler to fountain and secure with supplied hardware.

7.  Connect water supply and fountain drain. Connect drain waste "Tee" to fountain drain tubes. Connect outlet of "Tee" to 

     drainage system. Water connection and drain must comply with local codes.

8.  Turn on water supply and check all connections for leaks. 

CAUTION: This fountain is rated for inlet water pressure of 20-105 PSI. A pressure reducing regulator should be used if the 

 

inlet water supply exceeds 105 PSI. Any damage caused by reason of connecting this product to supply line 

 

pressures lower than 20 PSI or higher than 105 PSI is not covered by warranty.

  9.  Water supply 3/8" O.D. unplated copper  tube. Waste 1-1/2" IPS. Contractor to supply waste trap and service stop valve in

       accordance with local code.

10.  Connecting lines to be made of unplated copper and should be thoroughly flushed to remove all foreign matter before being 

       connected  to fountain. This fountain is manufactured in such a manner that it does not in any way cause taste, odor,color, 

       or sediment problems.

11.  Connect fountain to supply line with a shut-off valve and install a 3/8" unplated copper water line between the valve and 

       the fountain. Remove any burrs from outside of water line. Push the tubes straight into the fittings until they reach a

 

positive stop, approximately 3/4" (See Fig. 3). DO NOT SOLDER TUBES INSERTED INTO PLASTIC FITTINGS AS

 

DAMAGE TO THE O-RINGS MAY RESULT.

IMPORTANT

ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON

IMPORTANT! INSTALLER PLEASE NOTE.

THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES 

IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE 

BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN 

ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE 

WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN 

FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE 

FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.

INSTALLATION INSTRUCTIONS

WWW.RESTROOMDIRECT.COM      704•937•2673     129 Oakpark Dr., Unit A, Mooresville, NC 28115