RE926X_Flexible Bus WiFi Communicator

 

Page 

3

 of 

8

 

10-Mar-15 

24-hour Tech Support: (715)808-0164 

www.ResolutionProducts.com

 

 

DSC Power Series Programming:

 

 
Compatible DSC Panels: 

PC580 (Power 432)   

 

 

PC5020 (Power 864) 

PC1555 (Power 632)  

 

 

PC1616 

PC1555MX (Power 632) 

 

 

PC1832 

PC5010 (Power 832)  

 

 

PC1864 

PC5015 (Power 832)  

1)

 

Refer to server setup instructions and set up the account on the Dealer 
Portal. 

2)

 

Be sure to add a contact that uses the system MASTER CODE to the account before 
connecting the module. This will ensure the module can properly communicate 
with and configure required system settings. 

3)

 

Using the system’s Installer Code: 

a)

 

Disable the Communicator ([380]:[1]) 

b)

 

Disable the Telephone Line Monitor ([015]:[7]) 

c)

 

Delete Telephone Numbers (programming section 301-303) 

d)

 

Verify Alt Comm ([351]:[5]) is enabled 

4)

 

Verify Alarm report codes are setup properly for zones that are being used, 
1-64 (programming section 320-349). System will report as Burg(130) if 
programmed as FF. 

5)

 

If using Aux input (PGM2) verify Aux input report codes are setup properly 
(Programming section 329:4). System will report as Fire (110) if 
programmed as FF. 

6)

 

To enable reporting of the Period Test Transmission, program the “periodic 
Test Transmission” ([348]:[4]) and the “Periodic Test Transmission with 
Trouble” ([348]:[3]) reporting codes to “02” 

7)

 

All other reports are hardcoded in the gateway and cannot be changed 
regardless of what is entered in the programmed location. 

8)

 

Format and account number have no effect on reporting. 

9)

 

Disarm the system (all partitions) 

10)

 

Power down the DSC system. 

11)

 

 Set RE926X panel selector switch to DSC:    DSC    CDX   HW   UTC 

12)

 

 Connect the DSC Panel and RE926X as shown in the Wiring Instructions 
above. 

13)

 

Apply power to the DSC system.  

14)

 

The DSC control panel will begin automatic configuration. Can move to step 
14 during this time…  

15)

 

 WiFi Protected Setup connection to Router (see Operation – WiFi Protected 
Setup connection to Router) 

16)

 

Installation complete. 

 

 
 
 
 

RE926X_Flexible Bus WiFi Communicator

 

Page 

4

 of 

8

 

10-Mar-15 

24-hour Tech Support: (715)808-0164 

www.ResolutionProducts.com

 

 

Reporting Codes for DSC panels: 
 

The following table shows all events reported when connected to a DSC Panel. 

Event 

Report Code 

AC Fail/Restore 

301 

Panel Low Battery/Low Battery Restore 

302 

Opening/Closing Report 

400 

Cancel Report 

406 

Zone Alarm 

See below 

keypad fire panic 

110 

keypad aux panic 

100 

keypad police panic 

120 

Duress 

121 

Periodic Test Transmission 

602 

Periodic Test with Trouble Transmission 

608 

 
Automatic Contact ID is not supported. Manually programmed reporting codes 
are only supported for alarms on zones 1-64 ([320] – [324]) and for alarms on 
the PGM2/Aux input ([329]:[4]). The PGM2/Aux input is reported as zone 
number 99. 
 
If Report Codes have not been manually programmed for zone alarms, zone 
alarm reporting codes default to: 

 

Any zone alarm (zones 1-64): Code 1130 (Burglary) 

 

PGM2/Aux input (zone 99, likely a 2-wire Smoke): Code 1110 (Fire) 

 

Be sure to verify that all codes are being properly reported to the central 
station after you have installed the communicator module or modified any 
reporting program settings in the DSC installer programming menu. 

 

Trouble Shooting the Panel Connection:

 

If the “CS” or “Platform” LEDs are blinking, here are possible 
problems: 

Incorrect wiring 
Incorrect panel switch position 
Unsupported panel version 
Unsupported panel model 
Panel is in Installer Program mode 
Vista Specific: 

AUI not enabled 
AUI used for some other function 
LRR not enabled 
Another LRR or IP/GSM device connected to panel bus 

 

Factory Default Button and WPS button 

a)

 

Holding the Factory Default button for 5 seconds will reset the RE926X Communicator 

b)

 

Holding the Factory Default button for 10 seconds (LEDs will flash off 
twice) will set the RE926X to factory defaults 

c)

 

Press and Release the WPS button (WiFi Led flashes slowly) for 
connecting Primary Router 

d)

 

Press and Hold the WPS until WiFi LED flashes rapidly for connecting to Backup Router 

e)

 

Press and Hold the Factory Default button, then pressing the WPS button 
for approximately one second (Wifi LED will flash) to put the 
communicator into Access Point mode 