RE926X_Flexible Bus WiFi Communicator
Page
3
of
8
10-Mar-15
24-hour Tech Support: (715)808-0164
www.ResolutionProducts.com
DSC Power Series Programming:
Compatible DSC Panels:
PC580 (Power 432)
PC5020 (Power 864)
PC1555 (Power 632)
PC1616
PC1555MX (Power 632)
PC1832
PC5010 (Power 832)
PC1864
PC5015 (Power 832)
1)
Refer to server setup instructions and set up the account on the Dealer
Portal.
2)
Be sure to add a contact that uses the system MASTER CODE to the account before
connecting the module. This will ensure the module can properly communicate
with and configure required system settings.
3)
Using the system’s Installer Code:
a)
Disable the Communicator ([380]:[1])
b)
Disable the Telephone Line Monitor ([015]:[7])
c)
Delete Telephone Numbers (programming section 301-303)
d)
Verify Alt Comm ([351]:[5]) is enabled
4)
Verify Alarm report codes are setup properly for zones that are being used,
1-64 (programming section 320-349). System will report as Burg(130) if
programmed as FF.
5)
If using Aux input (PGM2) verify Aux input report codes are setup properly
(Programming section 329:4). System will report as Fire (110) if
programmed as FF.
6)
To enable reporting of the Period Test Transmission, program the “periodic
Test Transmission” ([348]:[4]) and the “Periodic Test Transmission with
Trouble” ([348]:[3]) reporting codes to “02”
7)
All other reports are hardcoded in the gateway and cannot be changed
regardless of what is entered in the programmed location.
8)
Format and account number have no effect on reporting.
9)
Disarm the system (all partitions)
10)
Power down the DSC system.
11)
Set RE926X panel selector switch to DSC: DSC CDX HW UTC
12)
Connect the DSC Panel and RE926X as shown in the Wiring Instructions
above.
13)
Apply power to the DSC system.
14)
The DSC control panel will begin automatic configuration. Can move to step
14 during this time…
15)
WiFi Protected Setup connection to Router (see Operation – WiFi Protected
Setup connection to Router)
16)
Installation complete.
RE926X_Flexible Bus WiFi Communicator
Page
4
of
8
10-Mar-15
24-hour Tech Support: (715)808-0164
www.ResolutionProducts.com
Reporting Codes for DSC panels:
The following table shows all events reported when connected to a DSC Panel.
Event
Report Code
AC Fail/Restore
301
Panel Low Battery/Low Battery Restore
302
Opening/Closing Report
400
Cancel Report
406
Zone Alarm
See below
keypad fire panic
110
keypad aux panic
100
keypad police panic
120
Duress
121
Periodic Test Transmission
602
Periodic Test with Trouble Transmission
608
Automatic Contact ID is not supported. Manually programmed reporting codes
are only supported for alarms on zones 1-64 ([320] – [324]) and for alarms on
the PGM2/Aux input ([329]:[4]). The PGM2/Aux input is reported as zone
number 99.
If Report Codes have not been manually programmed for zone alarms, zone
alarm reporting codes default to:
•
Any zone alarm (zones 1-64): Code 1130 (Burglary)
•
PGM2/Aux input (zone 99, likely a 2-wire Smoke): Code 1110 (Fire)
Be sure to verify that all codes are being properly reported to the central
station after you have installed the communicator module or modified any
reporting program settings in the DSC installer programming menu.
Trouble Shooting the Panel Connection:
If the “CS” or “Platform” LEDs are blinking, here are possible
problems:
Incorrect wiring
Incorrect panel switch position
Unsupported panel version
Unsupported panel model
Panel is in Installer Program mode
Vista Specific:
AUI not enabled
AUI used for some other function
LRR not enabled
Another LRR or IP/GSM device connected to panel bus
Factory Default Button and WPS button
a)
Holding the Factory Default button for 5 seconds will reset the RE926X Communicator
b)
Holding the Factory Default button for 10 seconds (LEDs will flash off
twice) will set the RE926X to factory defaults
c)
Press and Release the WPS button (WiFi Led flashes slowly) for
connecting Primary Router
d)
Press and Hold the WPS until WiFi LED flashes rapidly for connecting to Backup Router
e)
Press and Hold the Factory Default button, then pressing the WPS button
for approximately one second (Wifi LED will flash) to put the
communicator into Access Point mode