Resolution RE119 Скачать руководство пользователя страница 2

RE119_GE_Flood_Temp_Instructions

 

Page 

3

 of 

4

 

27-Jan-15 

24-Hour Tech Support Line: (715)808-0164 

www.ResolutionProducts.com

 

Specifications 

 

Flood sensing: 

Titanium contacts 
100K-Ohm nominal (DO NOT use an EOL resistor) 
Transmitter handles 1 or 2 flood elements, no more. 
0.04 inch floor spacing to eliminate floor 
condensation falses. 
Checks for moisture every 5 seconds: needs two 
positive moisture checks to send Flood alarm.  
(test mode: every second when cover is off) 

Freeze Alarm: 

45F +/- 2F 
Restores when temp increases 4F from alarm 

Overheat Alarm Temp: 

100F +/- 2F 
Restores when temp decreases 4F from alarm 

Mounting hardware: 

#6 or #8 screws 
Dual Mode mounting: 

 

Screwed to floor 

 

Screwed to wall 

Terminal wire capacity: 

16 Gauge 

Replacement Battery: 

CR123A 1550 mAH 

Temperature Range: 

0F to 120F 

Housing dimensions: 

3.3x1.4x1.1 inches 

 
Specifications subject to change without notice. 
 

Internal & Close-up Pictures

 

 
 
 
 

Temp Element

 

Strain relief for 
floor mounting

 

RE119_GE_Flood_Temp_Instructions

 

Page 

4

 of 

4

 

27-Jan-15 

24-Hour Tech Support Line: (715)808-0164 

www.ResolutionProducts.com

 

Notices

 

 
“GE”, “Honeywell”, and “DSC” are trademarks owned by General Electric Company, Honeywell 
International Inc., and Tyco Safety Products Canada LTD, respectively.   
 
Resolution Products, Inc. products will function with one of either GE, DSC or Honeywell systems.  
However, no Resolution product is produced by, endorsed by, nor is officially associated with GE, 
Honeywell or DSC.   Resolution recommends verifying proper enrollment and operation, per control 
panel installation instructions, at installation. 
 
Warranty 
Resolution Products, Inc. will replace products that are defective in their first five (5) years. 
 
FCC Notice 

This device complies with Part 15 of the FCC rules.  Operation is subject to the following two 
conditions: 

This device may not cause harmful interference. 
This device must accept any interference that may be received, including interference 
that may cause undesired operation. 

  
Changes or modifications not expressly approved by the Resolution Products, Inc. could void 
the user's authority to operate this equipment. 

 

FCC ID: U5X-RE101X 
 

 
IC Notice 

This device complies with Industry Canada license-exempt RSS standard(s). Operation is 
subject to the following two conditions: 
  

(1)This device may not cause interference, and 

  

(2)This device must accept any interference, including interference that may  

 cause undesired operation of the device. 
 
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils 
radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : 
  

(1)l'appareil ne doit pas produire de brouillage, et 

  

(2)l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, 

  

même si le brouillage est susceptible d'en compromettre le fonctionnement. 

  
IC: 8310A-RE101 
 
  

 

 

 

Отзывы: