RE119_GE_Flood_Temp_Instructions
Page
1
of
4
27-Jan-15
24-Hour Tech Support Line: (715)808-0164
www.ResolutionProducts.com
RE119
Flood/Temp Range, GE
®
-Compatible
Home Disaster™ Sensor
Features
•
Tri-Mode Environmental Sensing:
o
Flood/Moisture Sensor
o
Freeze – for Furnace Failure
o
Overheat – for Furnace runaway or Air Conditioning failure.
•
3 unique wireless IDs or Loops: one for each function
•
Cover tamper.
•
Strong, reliable RF signal.
•
8-10 year battery life on CR123A battery.
•
Low Battery indication.
•
3.3x1.4x1.1 inches.
Key Instructions
•
Battery “+” faces towards spring.
•
Activating Zones
Flood Zone operates on unit when it comes from the factory. The
enrolling actions (listed next) activate the Freeze and Overheat Zones.
ACTIVATE ONLY THE ZONES YOU NEED
(In order to extend battery life and prevent RF pollution):
•
Enrolling: Place control panel in enroll mode… then for…
Flood - Zone 0: RF DL ID ends in “0” (this RF DL ID is printed on sensor):
Enroll by:
•
…pressing & releasing Tamper
Sensor sends Flood Alarm & enrolls.
Freeze - Zone 1: RF DL ID ends in “1”:
Enroll by:
•
Holding Tamper down,
•
Leaving magnet away from Reed Switch,
•
…while installing battery.
Sensor sends Freeze-Alarm & enrolls.
Overheat – Zone 2: RF DL ID ends in “2”:
Enroll by:
•
Holding Tamper down,
•
Having magnet next to Reed Switch,
•
…while installing battery.
•
Sensor sends Overheat Alarm & enrolls.
RE119_GE_Flood_Temp_Instructions
Page
2
of
4
27-Jan-15
24-Hour Tech Support Line: (715)808-0164
www.ResolutionProducts.com
Operation
•
Flood (1
st
ID ending in 0)
Alarm: when liquid rises 0.040 inches above sensor bottom.
Tamper: when cover is opened.
Supervisory: every hour.
•
Freeze (2
nd
ID ending in 1)
Alarm: when room temperature drops below 40F.
Tamper: when cover is opened.
Supervisory: every hour.
•
Overheat (3
rd
ID ending in 2)
Alarm: when room temperature rises above 100F.
Tamper: when cover is opened.
Supervisory: every hour.