Operation
The factory default button
will reset the
communicator if held for approximately
5 seconds, and will factory default the
communicator if held for approximately 10
seconds.
•
All LEDs will flash off once when the
communicator is reset, and will flash
again when it is factory defaulted.
Cellular signal bar LEDs indicate the quality of
the cellular connection. A minimum of two
signal bar LEDs is recommended.
Signal Bar Cellular Signal Strength
0
Bad (0 to 14)
1
Marginal (15 to 19)
2
Acceptable (20 to 24)
3
Good (25 to 30)
4
Best (30+)
Cellular LED indicators
Factory Default Switch
Signal Bar LEDs
Cellular LED Indicators
LED
Indication
Power
(Green)
ON and Flashing off once
every second
- Powered
and running
Cellular
(Red)
ON
- Registered with the
local cellular network
CS
(Red)
ON
- Connected to central
station
Platform
(Yellow)
ON
- Connected to
interactive server