s p e a k e r o u t p u t
Power Switch
– When off, power is completely disconnected from the amplifier.
Fuse
– Replace only with time-lag fuse, IEC 60127 Type 3
Rating
– 100-120 VAC use 1.6 A, for 200-240 VAC use 1A
Mains power
– Connect to mains using IEC power cord.
Voltage Indication
– Be certain the Cantata m100 Amplifier has been configured for your local mains voltage.
RCA
– Connect to unbalanced source. 10 kOhm input impedance.
XLR
– Connect to balanced source. 20 kOhm input impedance, 10 kOhm per phase.
XLR connector pin configuration: pin 1 ground, pin 2 non-inverting (+), pin 3 inverting (-)
Speaker Outputs,
4mm Banana 2 sets provided
CAUTION! The differential circuitry employed in the m100 amplifier requires special attention when connecting
speakers. Do not connect negative speaker terminals of two amplifiers together. Do not connect the negative speaker
terminals to ground. Do not connect the m100 amplifier to a speaker selector device that employs a ground scheme, as
it may short-circuit the amplifier output. Be sure to observe proper polarity (red +, blue -). You can connect the yellow
jack to a loudspeaker ground if it is available.
1
2
3
4
5
6
7
Rear Panel
Power Connections and Main Power Switch
Analog Inputs
Analog Outputs