background image

RE224GH_GE-to-Honeywell_Translator.doc 

Page 1 of 4 

6/9/2011 

www.ResolutionProducts.com

 

 

 
Wireless  
Security  
Solutions 

 
 

RE224GH  GE

®

-to-Honeywell

®

 Wireless Translator™ 

 

Features 

 

Listens to GE protocol wireless devices: DWS, PIR, Glass Break, Fob, Panic. 

 

Transmits Honeywell protocol wireless. 

 

No sensor enrollment required.   

 

All sensor alarm, supervisory and trouble signals are passed through. 

 

Main device has its own unique ID for supervisories, complete reporting 
of main device tamper, external power supply fault and low battery. 

 

Dual antennas for both Receive and Transmit diversity for reliable range. 

 

Back-up battery protects during loss of external power. 

 

Key Instructions 

 

External supply:  12V DC at least 50 mA. 

 

3 AAA Alkaline batteries give 72 hours backup if external supply fails.  
INSTALL BATTERIES ONLY WHEN EXTERNAL SUPPLY IS READY TO CONNECT. 

 

Enrolling: 

 

Power the Translator.  It starts translating immediately.  
Sensors are NOT enrolled in the Translator. 

 

GE sensors may be enrolled into Honeywell system using 
the tripping enrollment mode.  They are not enrolled in the 
Translator. 

 

Enroll the Translator into a zone, because it sends check-in 
supervisories, cover tamper and low battery messages.   

 

Zone Type: 8 (24 hour Aux) – When cover opened: 
“fault” when system not armed, “alarm” when 
system armed. 

 

 Input Type: 3 (Supervised RF), Loop: 1 

 

When prompted, toggle the tamper switch to enroll 
the serial number. 

 

Operation 

 

 

Existing GE protocol sensors transmit as usual.  Translator passes 
information on to control panel as if they were Honeywell transmitters. 

 

GE Fob buttons:  

 

 

Lock/Unlock/Light/Star, Lock + Unlock  

translate to Honeywell Buttons:  Off/On/Left/nothing, Right 
   

 

 

 

 

[Loops 2/3/4/nothing, 1]

RE224GH_GE-to-Honeywell_Translator.doc 

Page 2 of 4 

6/9/2011 

www.ResolutionProducts.com

 

Translator Main Zone wireless transmission ( unique ID): 

Tamper, when cover opened.  Also sends restore. 
Low battery, when low battery.  Also sends restore. 
Supervisory every hour.  Supervisory stopped if 12V DC power absent. 

 

 

LED Operation 

 

Green LED 

 

On if 12V DC power present. 

 

Blinks on receipt of GE-compatible packets. 

 

Red LED 

 

On if device low battery (unless there’s no 12V DC 
power). 

 

Blinks on transmit of Honeywell-compatible packets. 

 

Application Diagram 

 

Because the Translator has two antennas, for both receive 
and transmit diversity, it will generally have better range 
than all sensors, and many panels (particularly those with 
internal antennas).   

 

Place the Translator generally in the center of the all the 
existing sensors it needs to hear.  It will have no problem 
reaching the control panel.

New 
Honeywell 
System 

New 
Honeywell 
Wireless

 

Sensors 

 

Existing GE 
Wireless 
Sensors 
 

Отзывы: