background image

RE124DG_DSC-to-GE_Wireless_Translator.doc 

Page 1 of 4 

9/3/2010 

www.ResolutionProducts.com

 

 

 
Wireless  
Security  
Solutions 

 
 

RE124DG  DSC

®

-to-GE

®

 Wireless Translator™ 

 

Features 

 

Listens to DSC protocol wireless devices. 

 

Transmits GE protocol wireless. 

 

Enrolls up to 63 devices. 

 

Unique wireless ID (or loop) for each zone, plus 1 for main device. 

 

All sensor alarm, supervisory and trouble signals are passed through. 

 

Dual antennas for both Receive and Transmit diversity for reliable range. 

 

Back-up battery operation. 

 

Complete supervision of tampers, external power supply fault and low 
battery. 

 

Key Instructions 

 

External supply:  12V DC at least 50 mA. 

 

3 AAA Alkaline batteries give 72 hours backup if external supply fails.  
INSTALL BATTERIES ONLY WHEN EXTERNAL SUPPLY IS READY TO CONNECT. 

 

Enrolling: 

 

Sensors 

1.

 

Press Enroll switch repeatedly until Device Type LED matches 
the type of device you’re enrolling.  ENROLLING AS WRONG 
DEVICE TYPE CAN CAUSE IMPROPER OPERATION. 

2.

 

Activate particular DSC sensor as follows: 

o

 

PIR:  Tamper – ENROLL PIRs FIRST 

o

 

Panic:  Button 

o

 

Key Fob:  Lower Right 

o

 

DWS:  Tamper 

3.

 

Automatic responses: 

o

 

Green LED blinks indicating receipt of DSC-compatible 
packets. 

o

 

Translator beeps indicating each enrollment into 
Translator. 

o

 

Red LED blinks indicating transmit of GE-compatible 
packet to panel. 

o

 

The Translator transmits packets to the panel as soon as 
it learns a new sensor.  So the panel, if it’s in enroll 
mode, will generally learn the GE-compatible packets 
simultaneously. 

 

Main device enrolled by tamper switch on the board.  Suggest 
enrolling in Group 10 in panel.  Translator itself never alarms, but its 
health needs to be monitored like a regular DWS. 
 

RE124DG_DSC-to-GE_Wireless_Translator.doc 

Page 2 of 4 

9/3/2010 

www.ResolutionProducts.com

 

 

Deleting: 

 

Delete all sensors:   

1.

 

Press enroll button repeatedly until all Device Type LEDs are 
off. 

2.

 

Press and hold enroll key for 5 seconds until beep. 

 

Delete one Device Type:   

1.

 

Press enroll button repeatedly until target Device Type LED is 
lit. 

2.

 

Press and hold enroll key for 5 seconds until beep. 

 

Operation 

 

 

Existing DSC protocol sensors transmit as usual.  Translator passes 
information on to control panel as if they were GE transmitters. 

 

DSC fob: Lower left = Lights, lower right = panic (= GE 
double button press), although can be non-alarm in panel. 
 

 

Translator Module Zone wireless transmission ( unique ID): 

Tamper, when cover opened.  Also sends restore. 
Low battery, when low battery.  Also sends restore. 
Supervisory every hour.  Supervisory stopped if 12V DC power absent. 
Translator Module does not send any alarm signals about itself. 

 

 

LED Operation 

 

Green LED 

 

On if 12V DC power present. 

 

Blinks on receipt of DSC-compatible packets. 

 

Red LED 

 

On if device low battery (unless there’s no 12V DC 
power). 

 

Blinks on transmit of GE-compatible packets. 

 

Application Diagram 

New GE 
Wireless 
System 

New GE 
Wireless 
Sensors 

 

Existing 
DSC 
Wireless 
Sensors 

 

Отзывы: