background image

DeltaSol

®

BS/4 V2

2

System-monitoring-display

Up to 4 Pt1000 temperature sensors

2 semiconductor relays for pump speed control

3 basic system layouts to choose from

Heat quantity measurement

RESOL VBus

®

Function control

Thermostat function (time-controlled)

Control of the system by RESOL ServiceCenter software possible

User-friendly operation

Housing with outstanding design

Extra-low power consumption

Содержание DeltaSol BS/4 V2

Страница 1: ...DeltaSol BS 4 V2 www solarhotwaterparts com au ...

Страница 2: ...ays for pump speed control 3 basic system layouts to choose from Heat quantity measurement RESOL VBus Function control Thermostat function time controlled Control of the system by RESOL ServiceCenter software possible User friendly operation Housing with outstanding design Extra low power consumption ...

Страница 3: ...DeltaSol BS 4 V2 3 hanging fixation display pushbutton can fuse 4A cable conduits with strain relief cover ...

Страница 4: ...ng display Tool bar to show actual status of the system Channel indication upper line text display lower line temperature or temperature difference display Relay activity Maximum store temperature exceeded Antifreeze function active Sensor fault Manual mode ...

Страница 5: ...DeltaSol BS 4 V2 5 Commissioning menu All vital adjustments for an easy commissioning ...

Страница 6: ...tut TSTB store temperature base TSTT store temperature top TDIS thermal disinfection temperaure TR temperature return if heat quantity measurement is active n current pump speed Operation hours h P operation hours h P1 operation hours relay 1 h P2 operation hours relay 2 Heat quantity kWh heat quantity in kWh if heat quantity measurement is active MWh heat quantity in MWh if heat quantity measurem...

Страница 7: ...u and press button 1 for approx two seconds after you have reached the last display item When an adjustment value is shown on the display SET is indicated to the right of the channel name Press button 3 in order to access the adjustment mode SET starts flashing Adjust the value using buttons 1 and 2 Briefly press button 3 SET permanently appears the adjusted value will be saved ...

Страница 8: ...DeltaSol BS 4 V2 8 Overview of system layouts Arr 1 standard solar system layout Arr 2 solar system layout with afterheating Arr 3 standard solar system layout with heat dump ...

Страница 9: ...DeltaSol BS 4 V2 9 System 1 ...

Страница 10: ...DeltaSol BS 4 V2 10 System 2 ...

Страница 11: ...DeltaSol BS 4 V2 11 System 3 ...

Страница 12: ...fference DT F DT1F DT2F DT3F Nominal temperature difference Maximum store temperature S MX S1MX S2MX Rise RIS RIS1 RIS2 RIS3 DT S DT1S DT2S DT3S Please note The controller is equipped with a security switch off of the store which avoids a further loading of the store if 95 C is reached at the store ...

Страница 13: ...DeltaSol BS 4 V2 13 Temperature limitation and antifreeze function Collector minimum limitation Collector emergency temp Collector minimum temp Antifreeze function Antifreeze temperature ...

Страница 14: ...ctor cooling blocked Cooling function Arr 3 no cooling functions but CMX switching condition for heat dump function Store cooling Holiday cooling S MX switch on condition More extensive cooling during times without DHW consumption additional ...

Страница 15: ...ainback option Drainback option activation Initialisation Switch on cond must be continuously fulfilled Filling time Pump at 100 Booster active Stabilisation Switch off conditions ignored while medium heats up Booster option ...

Страница 16: ...n Start end of time frame Pump runtime for measuring purpose Standstill interval between pump runtimes In a drainback system the filling and stabilising procedure will take place for each OTC pump runtime Evaluate if OTC activation is necessary ...

Страница 17: ...DeltaSol BS 4 V2 17 Thermal disinfection Disinfection temperature Starting delay time Disinfection period Monitoring period ...

Страница 18: ...2 thermostat function AH O AH F thermostat function for afterheating AH O AH F thermostat function for using surplus energy Use of surplus energy Afterheating Thermostat switch on temperature Thermostat switch off temperature ...

Страница 19: ...taSol BS 4 V2 19 Option heat quantity measurement Maximum flow in l min at 100 pump speed Concentration of antifreeze in VOL Type of antifreeze 0 water 1 propylene glycol 2 ethylne glycol 3 Tyfocor LS G LS ...

Страница 20: ...the minimum pump speed value nMN 30 If the temperature difference reaches the adjusted set value DT S the pump speed increases by one step 10 If the difference increases by 2 K RIS the pump speed increases by 10 respectively until the maximum pump speed of 100 is reached The response of the controller can be adapted via the parameter Rise If the temperature difference falls below the adjusted swit...

Страница 21: ... flashing LED red green flashing AUTO Relay in automatic operation ON Relay on flashing LED red green flashing Language dE German En English It Italian Fr French Temperature unit selection The unit can be switched between C K and F Ra during operation ...

Отзывы: