16
en
Adjustment channels
Channel
Description
Factory setting
Page
BHMN
s Thermostat comfort temperature
40 °C [110 °F]
BH O
s Switch-on temperature for thermostat
40 °C [110 °F]
BH F
s Switch-off temperature for thermostat
45 °C [120 °F]
t1 O
s Thermostat switch-on time 1
00:00
t1 F
s Thermostat switch-off time 1
00:00
t2 O
s Thermostat switch-on time 2
00:00
t2 F
s Thermostat switch-off time 2
00:00
t3 O
s Thermostat switch-on time 3
00:00
t3 F
s Thermostat switch-off time 3
00:00
BOOS
s Rapid heat-up runtime
90 min
ODB
x Drainback option
OFF
tDTO
x* ODB switch-on condition - time period
60 s
tFLL
x* ODB filling time
5.0 min
tSTB
x* ODB stabilisation time
2.0 min
OTD
s Thermal disinfection option
OFF
PDIS
s* Monitoring period
01:00
DDIS
s* Disinfection period
01:00
TDIS
s* Disinfection temperature
60 °C [140 °F]
SDIS
s* Starting time
00:00
MAN1
x Manual mode R1
On
MAN2
x Manual mode R2
OFF
LANG
x Language
dE
UNIT
x Temperature unit
°C
RESE
x Reset - back to factory settings
########
Version number
Symbol
Description
x
Channel is available
x*
Channel is available, if the corresponding option is activated.
s
System-specific channel
s*
System-specific channel, only available if the corresponding option is activated