To toggle between treatment screens 1 and 2, press 

 from your HOME screen.

 

9

Treatment with device 

trigger (Timed) and cycle 

(Timed, Ti Max or Ti Min) 

breath indicators

 

9

Treatment with spontaneous 

trigger and cycled breaths

Viewing the Info menu

The Info menu has a series of screens showing your sleep quality, sleep report and service information. 

To view the Info menu, push 

 from your HOME screen.

In the Sleep Quality screen, you 

can always view your usage 

hours during the last session 

and if enabled by your clinician, 

data on Mask Fit and AHI is 

displayed.

In the Sleep Report, only the 

period can be changed—other 

values are for display only.

In the Service information, the 

total device run hours (includes 

warm-up/cool-down times for 

the humidifier) and the software 

identifications are displayed.

To

 return to the HOME screen, push 

.

8

Содержание VPAP ST

Страница 1: ...Making quality of care easy Respiratory Care Solutions Welcome Guide English VPAP ST with iVAPS NONINVASIVE VENTILATOR...

Страница 2: ...Making quality of care easy Respiratory Care Solutions...

Страница 3: ...limLine air tubing 3 m air tubing ClimateLine heated air tubing ClimateLineMAX heated air tubing 30W power supply unit does not support H5i Power Station II battery pack DC DC Converter 24V 90W Travel...

Страница 4: ...r end of the power cord into the power outlet 4 Connect one end of the air tubing firmly onto the air outlet 5 Connect the assembled mask system to the free end of the air tubing Notes For more inform...

Страница 5: ...s or exit from the menu Push dial Turning the dial allows you to scroll through the menu and change settings Pushing the dial allows you to enter into a menu and confirm your choice Start Stop button...

Страница 6: ...oice Using Mask Fit You can use Mask Fit to help you fit your mask properly This feature delivers CPAP pressure for a three minute period prior to starting treatment during which you can check and adj...

Страница 7: ...humidification and Climate Control Selecting the mask type To select your type of mask 1 Press The SETTINGS screen is displayed 2 Turn until Mask is displayed in blue 3 Press The selection is highligh...

Страница 8: ...5 Lie down and arrange the air tubing so that it is free to move if you turn in your sleep 6 To stop treatment at any time remove your mask and or press Notes If your clinician has enabled SmartStart...

Страница 9: ...eLine or ClimateLineMAX 9 9 Climate Control Manual 9 9 Therapy data without optional accessories 9 9 Oximetry data via the oximeter adapter Pressure bar In bilevel modes the fixed vertical lines on th...

Страница 10: ...report and service information To view the Info menu push from your HOME screen In the Sleep Quality screen you can always view your usage hours during the last session and if enabled by your clinicia...

Страница 11: ...n warm water using mild detergent 3 Rinse thoroughly hang and allow to dry 4 Before next use reconnect the air tubing to the air outlet and mask Monthly 1 Wipe the exterior of the device with a damp c...

Страница 12: ...the card 1 Push in the SD card to release it 2 Remove the card 3 Insert the card into the protective folder 4 Send the protective folder back to your clinician as instructed For more information on re...