When used with the Mobility Bag, always ensure the External 

Battery is secured in the External Battery compartment 

(

illustration

 

D

). The Mobility bag is capable of holding only 

one External Battery. Refer to the Mobility Bag User Guide for 
instructions.

Air travel

Consult with your carrier if you intend to take the External 

Battery on board with your device.
When travelling with the External Battery:

 

• For your convenience at security stations, it may be helpful to 

keep a printed copy of the External Battery User Guide to help 

security personnel understand the device and refer them to 

the following statements:

 

• ResMed confirms that the External Battery meets the 

Federal Aviation Administration (FAA) requirements (RTCA/

DO-160, section 21, category M) for all phases of air travel.

 

• ResMed comfirms that the External Battery meets IATA 

classification: UN 3480 – Lithium-ion batteries.

Cleaning and maintenance

The cleaning and maintenance described in this section should 

be carried out regularly.
Wipe the exterior of the battery with a clean slightly damp cloth.
Refer to the User Guides for the patient interface, humidifier and 

other accessories in use for detailed instructions for care and 

maintenance of those devices.

 CAUTION

 

Clean only exterior surfaces of the External Battery.

 

Do not immerse the External Battery in water, and do 
not pour liquids or solvents onto any part of the External 
Battery.

The following cleaning solutions are compatible for use on a 

weekly basis (except as noted) when cleaning the external 

surfaces of the Astral device:

 

• Isopropanol

 

• Actichlor Plus

 

• Bleach (1:10) (may also be known as ‘dilute hypochlorite’).

 

• Cavicide*

 

• Mikrozid*

   *Suitable for cleaning on a monthly basis only.

Storage

Ensure that the External Battery is clean and dry before storing 

for any length of time. Store the External Battery in a dry place 

out of direct sunlight.

 CAUTION

 

The External Battery must be charged to at least 65-90% 
(indicated by three green LEDs) and switched off before 
storing.

 

When not in use, all Lithium-ion batteries self-discharge 
over time. Recharge the External Battery to at least 65-90% 
after six months of storage. 

Содержание Astral External Battery

Страница 1: ...User guide English...

Страница 2: ...B A 1 2 3 4 5 6...

Страница 3: ...eneral warnings and cautions Further specific warnings cautions and notes appear next to the relevant instruction in the user guide A warning alerts you to possible injury WARNING The battery is to be...

Страница 4: ...n the battery Ensure the External Battery is kept dry Do not expose to water rain or high moisture levels Indicators Refer to illustration A The capacity and operation of the External Battery are indi...

Страница 5: ...rge Maintenance displays the full charge capacity and the charge cycle count for any batteries currently detected by the system Regularly check the charge level of the external battery It is recommend...

Страница 6: ...ct the External Battery DC output cable into the DC input port of the Astral device 2 Connect the AC power supply cable to the DC input port of the External Battery 3 Plug the other end of the AC powe...

Страница 7: ...ttery alarm before swapping over to the other external battery The Astral device will continue to ventilate using the internal battery while the external batteries are swapped WARNING The internal bat...

Страница 8: ...uld be carried out regularly Wipe the exterior of the battery with a clean slightly damp cloth Refer to the User Guides for the patient interface humidifier and other accessories in use for detailed i...

Страница 9: ...ated Power connections are disrupted Check all cables and connect them as described in Setting up External Battery is discharged Connect the device to the mains power supply and recharge the External...

Страница 10: ...400 charge cycles at 23 C to 80 capacity Operating conditions Charging Discharging 10 C to 35 C 5 93 maximum humidity 0 C to 40 C 5 93 maximum humidity Transport storage conditions 20 C to 50 C 5 93 r...

Страница 11: ...transport External Battery charge level External Battery charging indicator Direct current O I DC on off DC Input port DC Output Do not use if package is damaged Canadian Standards Association Manufac...

Страница 12: ...ices 2 years This warranty is only available to the initial consumer It is not transferable If the product fails under conditions of normal use ResMed will repair or replace at its option the defectiv...

Страница 13: ...limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from region to region For further information on your warranty rights conta...

Страница 14: ...1 2 3 C D...

Страница 15: ...de Astral is a trademark and or registered trademark of the ResMed family of companies For patent and other intellectual property information see ResMed com ip Actichlor is a trademark of Ecolab US In...

Отзывы: