LOCATION GUIDELINES

 

The FG-1625R/RT detects framed glass broken by an impact sufficient to make a hole. 

Refer to the following guidelines when selecting a mounting location:

 

 The FG-1625R/RT can be mounted in corners, on walls, and on ceilings.

 

 Mount within 25’ (7.6 m) of the glass.

 

 There is no minimum range, but the detector must have a clear line-of-sight and a 

clear view of the glass.

 

 The ideal location is on the wall or ceiling directly opposite the glass. The least 

desirable location is on the same wall as the glass.

 

 When wall mounting, mount the detector a minimum of 6’ (1.8 m) high.

 

 Curtains, blinds and other window coverings absorb energy from breaking glass. 

Heavy curtains, for example, effectively block the sound signal. In these cases, 

mount the detector on the window frame behind the window covering or above the 

window.

 

 Do not mount within 3’ (0.9 m) of forced air ducts, sirens, or bells measuring 2” (5 

cm) or more in diameter.

 

 Minimize range to the glass. Do not install beyond the maximum specified range 

even if testing indicates greater range.

 

 Adjust sensitivity for desired range; verify by testing with the FG-701.

 

 Mounting on freestanding posts and pillars is not recommended.

 

 Verify all installations back to the panel to be sure the protection loop is intact.

 

 Do not use outside.

 

 Avoid installing in rooms with high-level noise sources, such as air compressors, 

bells, and power tools if those sources can be active when the detector can 

signal an alarm.

 

 Test false alarm immunity by activating any noise sources in the room.

 

Note: 

The FG-1625R/RT detects shattering of framed glass by a direct impact. It may 

not consistently detect breakage by blows that only crack the glass, by high velocity 

projectiles (such as bullets) or if the glass is broken without an impact.

 

 

USING THE CEILING/WALL TAMPER SWITCH (FG-1625RT ONLY)

 

The FG-1625RT has a combination normally-closed (NC) cover and wall tamper. 

Each detector is shipped with the cover tamper operational and the ceiling/wall 

tamper disabled.

 

  Use needle-nose pliers to break out the plastic tab on the back of the detector. The 

tamper arm then extends through the hole.  

  The tamper screw (not provided) should be a flat-head #8 (4.2 mm) or Tamper 

#10 (4.8 mm) screw. 

  Install  the  tamper  screw  so  it  will  just  make 

contact  with  the  bottom  of  the  mounted 

detector’s tamper cavity. 

  After installing the tamper screw,  position the 

detector over it and mark

 

the locations for the mounting screws. 

 

 

LED INDICATORS

 

The two LEDs on the front cover indicate the detector's operational status. The 

following table summarizes the LED operation when the LEDs are enabled.

 

 

 

 

 

 

 

 

 

 

 

 

Protected glass:

 

Minimum size for all types is 11 inches (28 cm) square. Glass must be framed in the wall of the 

room or mounted in a barrier of 36 inches (0.9 m) minimum width.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Protected only if both glass plates are broken.

 

Coated glass with security films up to 0.35mm (14 mils) thick (including films for solar 

protection) may be used. Evaluated with these products: 3M

® 

SCOTCHSHIELD

® 

SH14CLARL – 0.35mm

 

(14 mils), 4 ply film; Film Technologies International, Inc.’s GLASS-GARD

® 

GGLL 1200 – 

0.3mm

 

(12 mils), 3 ply film by Underwriters Laboratories, Inc., at Resideo’s request.

 

In compliance with Underwriters Laboratories of Canada’s Standard for Intrusion 

Detection Units (CAN/ULC-S306-M89)

 

ULC recognizes a maximum range of 6m (20 ft.) for protecting 2mm (3/32”) plate and and 

3mm (1/8”) laminated.

 

ULC recognizes a maximum range for protecting 3mm (1/8”) sealed insulating glass and 

all coated glass of 4m (12.5 ft.).

 

UL recognizes a maximum range for protecting 3mm (1/8”) sealed insulating glass of 6m (20 

ft.) with sensitivity set at maximum.

 

IMPORTANT: 

The FG-1625R/RT must be connected to a UL listed power 

supply or UL listed control unit capable of providing 

a minimum of four hours 

of standby power. 

 

2 Corporate Center Drive, Suite 100 

P.O. Box 9040, Melville, NY 11747 

 2020 Resideo Technologies, Inc.  

www.resideo.com

 

SPECIFICATIONS

 

Range: 

Operating temperature:

 

25 feet (7.6 m) maximum 

14° F to 131°F (-10° C to 55°C)

 

No minimum range 

UL: 14° F to 122°F (-10° C to 50°C)

 

Alarm relay: 

(Indoor use environment)

 

FG-1625R Form A 

Storage: -4° F to 131° F (-20° C to 55° C)

 

FG-1625RT Form C 

-4° F to 122° F (-20° C to 50° C)

 

100 mA maximum 

ESD immunity:

 

25 VDC maximum 

10 kV, Discharges of either polarity to exposed

 

ON/closed 22

ʌ

 ±6

ʌ

 

surfaces

 

OFF/open >1M

ʌ

 

Dimensions:

 

Alarm duration: 

4.25” OD x 0.88” THK 5 

seconds (unaffected by alarm LED 

(108 mm x 22.4 mm) 

latching) 

Weight:

 

Tamper switch: (FG-1625RT only) 

4.5 oz., (128 g)

 

Combination cover and wall tamper 

Packaged product: 7.5 oz., (213 g) 25 

mA maximum 

Accessories:

 

24 VDC maximum 

FG-701 Glassbreak Simulator

 

Power requirements: 

FG-SP2 Spacer Plate

 

8 - 16 VDC; 12 mA typical at 

Approvals/Listings:

 

12 VDC, 22 mA max.; 

FCC and IC Verified

 

AC Ripple: 4 Volts peak-to-peak 

UL Listed

 

at nominal 12 VDC 

ULC Listed

 

RFI immunity: 

CE

 

30 V/m, 10 MHz - 1000 MHz 

FG-1625RT only:

 

ESD immunity: 

EN 50131-1, Grade 2, Class II

 

10 kV, Discharges of either polarity to 

Suitable for connection to an EN 60950 Class II 

exposed surfaces 

Limited Power Source

 

Responsible Party / Issuer of Supplier’s Declaration of Conformity: Ademco Inc., a subsidiary 

of Resideo Technologies, Inc., 2 Corporate Center Drive., Melville, NY 11747, Ph: 516-577-

2000

 

For any additional information regarding the compliance of this product to any EU specific requirements, 

please contact:

 

Sécurité Communication 

1198, Avenue du Docteur Maurice Donat 

BP 1219 - 06254 MOUGINS CEDEX, FRANCE 

Tel.: +33 (0)4 92 94 29 50 

fax: +33 (0)4 92 94 29 60. 

NOTICES

 

FCC NOTICE: 

This equipment has been tested and found to comply with the limits for a Class 

B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide 

reasonable protection against harmful interference in a residential installation. This equipment 

generates, uses, and can radiate radio frequency energy and, if not installed and used in 

accordance with the instructions, may cause harmful interference to radio communications. 

However, there is no guarantee that interference will not occur in a particular installation. If 

this equipment does cause harmful interference to radio or television reception, which can be 

determined by turning the equipment off and on, the user is encouraged to try to correct the 

interference by one or more of the following measures: 1) Reorient or relocate the receiving 

antenna, 2) Increase the separation between the equipment and receiver, 3) Connect the 

equipment into an outlet on a circuit different from that to which the receiver is connected,

 

4) Consult the dealer or an experienced radio/television technician for help.

 

The user is cautioned that changes or modifications not expressly approved by Resideo 

could void the user’s authority to operate this equipment.

 

IC Notice: 

This Class B digital device apparatus complies with the Canadian standard 

ICES-003. Cet appareil numérique de la Classe B est conforme à la norme NMB-003 

du Canada. 

 

 

Ê5-051-738-00F*Š 

This product is manufactured by Resideo and its affiliates.

 

 

For the latest U.S. warranty information, please go to: www.resideo.com or Please contact your local 

authorized Resideo representative for product warranty information.

 

5-051-738-0

0F   7/14   Rev. F

 

Condition 

Green LED 

Red LED

 

Normal

 

OFF

 

OFF

 

Normal, event detected

 

Flicker

 

OFF

 

Normal, break detected

 

OFF

 

ON 5 seconds

 

Normal, alarm latched

 

OFF

 

ON continuously

 

Power up

 

ON 1 second

 

ON 1 second

 

Low voltage

 

Flash ON/OFF

 

Flash ON/OFF

 

Test Mode

 

Flash once per second

 

OFF

 

Test Mode, event detected

 

Flicker

 

OFF

 

Test Mode, alarm

 

Flash once per second

 

ON 5 seconds

 

 

 

Type

 

Thickness

 

Minimum

 

Maximum

 

Plate 

3a,4

 

3/32” (2 mm)

 

3/8” (10 mm)

 

Tempered

 

1/8” (3 mm)

 

3/8” (10 mm)

 

Laminated 

1,3a

 

1/8” (3 mm)

 

9/16” (14 mm)

 

Wired 

3a

 

1/4” (6 mm)

 

1/4” (6 mm)

 

Coated 

2,3b

 

1/8” (3 mm)

 

1/4” (6 mm)

 

Sealed Insulating 

1,3b,4

 

1/8” (3 mm)

 

1/4” (6 mm)

 

 

[1/2” (13 mm overall)]

 

[3/4” (19 mm overall)]

 

 