FlexGuard® FG-1625R/FG-1625RT Glassbreak Detectector Installation Instructions

 

 

 

 

 

Mount the detector.

 

For location guidelines, refer to the Supplemental 

Information on the back page.

 

Note: 

If you plan to use the wall tamper, locate the 

wall tamper screw position before the mounting 

screws position. Refer to the Supplemental Informa- 

tion for instructions on using the wall tamper.

 

 

Use a screwdriver to push down on the latch at the 

side of the detector to remove the front  cover.

 

Note: 

Do not remove the PCB from the protective 

enclosure.

 

 

For surface wiring, use the FG-SP2 spacer  plate 

provided.

 

 

Secure the detector with #6 (3.5 mm) or #8 (4.2 

mm) screws (not provided).

 

 

Wire the detector.

 

 

Route the wire through the wire entry 

hole in the PCB center. Cut and strip wire 

ends 1/4 inch  (6.0 mm).

 

 

Wire the detector using 18-22 AWG 

(0.64 mm  to

 

1.02 mm). Reverse polarity connections will 

not damage the detector. For proper wiring 

methods, refer to the National Electrical 

Code NFPA 70.

 

 

After completing wiring, push excess 

wire back into the wall and replace the front 

cover.

 

Note: 

You can secure the cover with a #4 

(2.9 mm) screw if required. The hole is 

located on the intermediate cover near the 

latch. 

 

 

 

 

 

TIP: 

Temporarily mount the detector in the intended location and power it with a 9 V battery until testing 

establishes effective range coverage. If the 9 V battery is low, both LEDs will  flash.

 

 

Configure the detector.

 

The following tables show how to configure DIP 

switch S4 to best suit the application. The 

illustration shows you the default settings.

 

 

SENSITIVITY

1

 

SENS1

 

SENS2

 

APPROX. 

RANGE

 

Max

 

OFF

 

OFF

 

25’ (7.6 m)

 

Med

 

ON

 

OFF

 

15’ (4.6 m)

 

Low

 

OFF

 

ON

 

10’ (3 m)

 

 

SWITCH

 

OFF

 

ON

 

 

LATCH

 

Red Alarm LED lights for 

5 seconds during alarm.

 

Red Alarm LED latches 

ON when detector 

goes into alarm.

2,3

 

 

LED

 

LEDs are disabled 

except during power-up 

and Test Mode. 

4

 

LEDs are always enabled.

 

No effect in Remote LED 

Enable/Disable Mode.

 

1

Verify range with the FG-701.

 

2

The timing of the alarm relay is not affected by the latched Alarm LED.

 

3

Reset the Alarm LED by removing and restoring power, or by toggling the detector in 

and out of test mode.

 

4

LEDs can be enabled or disabled with the FG-701.

 

 

 

Test the detector.

 

Note: 

Test the FG-1625R/RT at least once each 

year.

 

Test the detector with the FG-701 Glassbreak 

Simulator. The FG-700 can be used if set for 

Tempered glass sound.

 

Activating Test Mode

 

1

 

Position the simulator within 15’ (4.6 m) of the 

FG-1625R/RT detector.

 

2

 

Switch the FG-701 simulator to ACTIVATE 

and MANual modes.

 

3

 

Point the front speaker of the simulator at the 

detector and press the red start button.

 

The simulator buzzes, and the green LED on 

the FG-1625R/RT flashes about once per 

second to indicate it is in Test Mode.

 

If an FG-701 is not available, or if for any reason 

remote activation cannot be used, use a small 

screwdriver to short the test pads on the PCB. This 

activates Test Mode.

 

Make sure to replace the front cover of the unit before testing.

 

Testing the FG-1625R/RT

 

1

 

Set the FG-701 switches to the TEST and FLEX positions.

 

2

 

Position the FG-701 near the farthest point of the  glass 

and point the speaker directly at the FG-1625R/ RT. If window 

coverings are present, close them fully and hold the FG-701 

behind  them.

 

3

 

Press the red start button. The simulator “clicks” on and 

starts an 8 second armed  period.

 

4

 

Generate a flex signal by carefully striking the glass with a 

cushioned tool. The FG-701 responds by producing a burst of 

glassbreak  audio.

 

If the FG-1625R/RT properly receives both the simulator flex 

and audio, the red alarm LED lights.

 

 

Note: 

Some environmental factors may reduce the detector activation 

range. If after pressing the red start button you do not see the green     LED 

flashing, move closer to the detector and try again.

 

Testing the Audio Alone

 

You can also use the simulator in the MANual mode to test  audio alone. The 

green LED on the detector flickers when the detector properly receives the 

simulator audio. (See the FG-701 Operating Instructions for additional 

information.) Keep in mind this is not a complete  test.

 

Exiting Test Mode

 

After testing, exit Test Mode using the same procedure for activating Test 

Mode. The FG-1625R/RT automatically exits the Test Mode 5 minutes after the 

last event is detected.

 

REMOTE LED ENABLE/DISABLE MODE

 

The detector’s  Remote LED Enable/Disable Mode allows you to enable  or 

disable the detector’s LEDs with the FG-701 Glassbreak Simulator.

 

To enable or disable the LEDs with the FG-701:

 

1.

  Set LED switch, S4 position 4, to  off.

 

2.

  Enter Test Mode, and then exit Test Mode.

 

3.

  Within  two  (2)  seconds,  enter  Test  Mode  again;  this  changes LED 

enable/disable status.

 

4.

  Exit Test Mode again.

 

5.

  Clap your hands to test the LEDs. If enabled, the green LED  will  flicker.  If 

disabled, the green LED will remain off.

 