resideo Braukmann MiniPlus FF06 Скачать руководство пользователя страница 2

GB

2

MU1H-1115GE23 R0220

1

Safety Guidelines

1.

Follow the installation instructions.

2.

Use the appliance
• according to its intended use
• in good condition
• with due regard to safety and risk of danger.

3.

Note that the appliance is exclusively for use in the 
applications detailed in these installation instructions 
(see 2 Technical Data). Any other use will not be 
considered to comply with requirements and would 
invalidate the warranty.

4.

Please take note that any assembly, commissioning, 
servicing and adjustment work may only be carried 
out by authorized persons.

5.

Immediately rectify any malfunctions which may 
influence safety.

2

Technical Data

2.1 FF06

Note:

The filter is constructed for drinking water installations. In 
case of a process water application the filter has to be 
proven individually.

2.2 FF06-AAM

Note:

The filter is constructed for drinking water installations. In 
case of a process water application the filter has to be 
proven individually.

3

Options

For Options visit homecomfort.resideo.com/europe

4

Assembly

4.1 Installation Guidelines

Install in horizontal pipework with filter bowl 
downwards
– This position ensures optimum filter efficiency

Install shut-off valves

These filters are armatures which need to be 
maintained regularly

Ensure good access
– Degree of contamination can be easily seen with 

clear filter bowl

– Simplifies maintenance and inspection

The installation location should be protected against 
frost

Related to the EN 806-2 it is recommended to install 
the filter immediately after the water meter

In order to avoid flooding, it is recommended to 
arrange a permanent, professionally dimensioned 
wastewater connection

4.2 Assembly instructions

We recommend to install an inlet check valve 

CAUTION!
Observe the flow direction when mounting the 
backflow preventer.

CAUTION!
When connecting the solder sockets, do not solder 
the sockets together with the filter. High 
temperatures destroy internal parts which are 
important to the function!

1.

Thoroughly flush pipework

2.

Install filter
• Note flow direction
• Install without tension or bending stresses

Media

Medium: Drinking 

water

Connections/Sizes

Connection sizes: 

1

/

2

" - 1

1

/

4

Pressure values

Max. operating pressure: 

16 bar

Operating temperatures

Max. operating temperature 
medium accord. to EN 1567: 

30 °C

Specifications

Installation position: 

Horizontal with filter bowl 
downwards 

Media

Medium: Drinking 

water

Connections/Sizes

Connection sizes: 

1

/

2

" - 1

1

/

4

Pressure values

Max. operating pressure: 

25 bar

Operating temperatures

Max. operating temperature 
medium: 

70 °C

Specifications

Installation position: 

Horizontal with filter bowl 
downwards 

Отзывы: