![resideo 5800PIR-OD2 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/resideo/5800pir-od2/5800pir-od2_installation-and-setup-manual_1443936002.webp)
-2-
Coverage Area Angle
The coverage area will always be 90° with 13 zones, and can be adjusted to 7
different angles from A to G. It comes defaulted at the D setting. Turn the Pyro-
Electrics firmly until it clicks into the desired angle indicated by the arrows at the
bottom with the respect to the letters.
PIR Sensitivity
The sensitivity of the PIR can be adjusted from Low to Medium to
High, represented as L, M, and H. The setting is on the right-hand
side, behind the flange, next to the top pyro-electric.To adjust the
PIR sensitivity, push the sensitivity selector up or down until it
indicates L, M, or H.
Detection Range
The detection range is determined by the bottom Pyro-
Electric. The top Pyro-Electric remains stationary and is
aimed parallel to the ground. To change the detection
range, simply grasp the bottom Pyro-electric and firmly
move it up or down to the desired setting indicated by
the embossed arrow on the bottom-left corner of the
Pyro Electric. These settings are based on a mounting
height of 3.3ft (1 meter). The height of the motion
detector will affect the detection range. Additionally, the
detection range may vary due to environmental
conditions (heavy rain or snow, fog, etc.).
5800™ Series transmitters draw quick bursts of current during transmission, then sit idle with very nominal current draw. Most
batteries are not designed for this type of use, therefore, only batteries listed as compatible should be used if the expected
ba
ttery life is to be attained. Each transmitter’s Installation Instructions has listed compatible battery manufacturers and their
part numbers. When other non-approved batteries are used, the quick bursts of current draw kill the battery cells prematurely
causing them to go low in a matter of months and can also cause unpredictable results. Other low quality batteries have not
been UL tested and pose a safety hazard if used.