background image

 

 

Alarm Relay Contact 

Relay outputs with current carrying capacity of 1 A 
@24VDC,   
Relay in short circuit mode when 2 powers are 
connected. in open circuit mode when only one 
power supply is connected 

POE power 

n/a 

Removable Terminal Block 

Provide 2 Redundant power , Alarm relay contact ,6 
Pin 
Wire range: 0.34mm^2 to 2.5mm^2 
Solid wire (AWG):12-24/14-22 
Stranded wire(AWG): 12-24/14-22 
Torque:5lb-In/0.5Nm/0.56Nm 
Wire Strip length: 7-8mm 

Operating Temperature 

-40

~75

 fully tested.  

Operating Humidity 

5% to 95% (Non-condensing) 

Storage Temperature 

-40

~85

 

MTBF (mean time between 
failure) 

510,304 hrs ( MIL-HDBK-217F) at 25°C 

Housing  

Rugged Metal ,IP30 Protection 

Case Dimension (L x W x D) 

142mmx36.2mmx105mm (LxWxD) 

Installation mounting  

DIN Rail mounting and Wall Mounting  

 
Certifications: 

EN55022/24  

ITE equipment 

EN55011 

Industrial, Scientific and Medical (ISM) equipment 

Safety 

IEC EN60950-1 

EMC/EMS   

CE, FCC, VCCI 

EMI 

FCC Part 15 Subpart B Class A,  
CE EN 55022 Class A 

EN 50155 / EN 60068-2-6 

Vibration 

EN 50155 / EN 60068-2-27 

Shock 

EN 50155 / EN 60068-2-32 

Free Fall 

 

Содержание RP-ISF800

Страница 1: ...omplies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation CE MARKING This equipment complies with the requirements relating to electromagnetic compatibility EN 55022 class A for ITE the essential protecti...

Страница 2: ...2 powers are connected the relay is in OPEN mode When any power source fails the relay change to SHORT status Power connecting procedure STEP 1 Pull out 6 pin terminal block STEP 2 Connect wire to V1 V1 or V2 V2 and Ground the neutral wire to the ground screw STEP 3 Plug back 6 pin terminal block to its place WARNING Always ground the power source to maintain a clean power input Due to too many ch...

Страница 3: ...cted LED indicator PW2 ON when V2 V2 is connected This unit has no POE feature the POE amber LED will always stays in OFF status Green LED ON Link Flash TX RX Relay LED Amber ON one power is connected OFF two powers are connected ...

Страница 4: ... Table Size 1K Packet Buffer Size 1M Network Connector 8xRJ 45 10 100BaseT X auto negotiation Auto MDI MDI X function Full Half duplex Network Cable UTP STP above Cat 5e Cable EIA TIA 568 10 ohm 100m Protocol CSMA CD LED PW1 Power 1 Green PW2 Power 2 Green SW relay Amber TX RJ 45 port LNK Link Active Green Housing Heavy Metal Housing Reserve polarity protection Present Overload current protection ...

Страница 5: ...length 7 8mm Operating Temperature 40 75 fully tested Operating Humidity 5 to 95 Non condensing Storage Temperature 40 85 MTBF mean time between failure 510 304 hrs MIL HDBK 217F at 25 C Housing Rugged Metal IP30 Protection Case Dimension L x W x D 142mmx36 2mmx105mm LxWxD Installation mounting DIN Rail mounting and Wall Mounting Certifications EN55022 24 ITE equipment EN55011 Industrial Scientifi...

Страница 6: ...6 Housing Dimension ...

Отзывы: