Power connecting procedure: 

   
STEP 1 – Pull out 6 pin terminal block. 
STEP 2 – Connect wire to P1+, P1-, P2+, P2-, 

and the neutral wire to the ground screw.

 

STEP 3– Plug connected 6 pin terminal block back into place. 
Or, Connect the P3 power DIN from external power adapter.   

 
WARNING -- Always SHUT OFF power source to connect power wire. 
WARNING -- Always ground the power source to maintain a clean power input. Cheaply 
made power supplies create too much noise and will cause the power input to fluctuate 
when connected to this unit. To avoid this, always ground the power source to maintain a 
clean power input.

 

 

Содержание RP-IPG814-2F

Страница 1: ...dential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This device complies with Part 15 of the FCC Rules Operation...

Страница 2: ...to your PD devices All 16 ports are independent and can all be used for easy expansion of your network application With our unique Cold Design technology it will not only power up your PD and also red...

Страница 3: ...h 3 power input sources P1 P2 and P3 To connect power Follow the printed polarity for P1 P1 P2 P2 and ground Connect positive wires to P1 and or P2 connect negative wires to P1 and or P2 and connect t...

Страница 4: ...o place Or Connect the P3 power DIN from external power adapter WARNING Always SHUT OFF power source to connect power wire WARNING Always ground the power source to maintain a clean power input Cheapl...

Страница 5: ...g TX port is active F15 F16 Green ON F15 or F16 SFP fiber is detected OFF F15 or F16 SFP fiber is not detected Flashing F15 or F16 SFP fiber is active P1 Green ON P1 P1 is connected P2 Green ON P2 P2...

Страница 6: ...ion Auto MDI MDI X function Full Half duplex 14 x Gigabit POE 802 3at af PSE port 30W per port 2 x SFP 1000M Network Cable UTP STP Cat 5e or above Cable EIA TIA 568 100m Protocol CSMA CD LED PW1 Green...

Страница 7: ...m 2 Solid wire AWG 12 24 14 22 Stranded wire AWG 12 24 14 22 Torque 5lb In 0 5Nm 0 56Nm Wire Strip length 7 8mm Operating Temperature 40 C to 75 C Operating Humidity 5 to 95 Non condensing Storage Tem...

Страница 8: ...8 Housing Dimension mm...

Отзывы: