background image

Trademarks: 

All trade names and trademarks are the properties of their respective companies. 

Copyright © 2022, All Rights Reserved. 

 

 

 

User manual 

Hardened Industrial 16 port Gigabit PoE Switch, 14 x 10/100/1000M TX 30W PSE + 2 x 1000M SFP, 

48-56VDC input voltage, operating temp.: -40°C to +75°C 

 

FCC MARKING 

 
This Equipment has been tested and found to comply with the limits for a Class A 
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to 
provide reasonable protection against harmful

 

interference

 

when the

 

equipment is 

operated in a commercial environment. This equipment generates, uses, and can 
radiate radio frequency energy and, if not installed and used in accordance with the 
instruction manual, may cause harmful interference to radio communications. 
Operation of this equipment in a residential area is likely to cause harmful 
interference in which case the user will be required to correct the interference at his 
own expense. 
This device complies with Part 15 of the FCC Rules. Operation is subject to the 
following two conditions: (1) this device may not cause harmful interference, and (2) 
this device must accept any interference received; including interference that may 
cause undesired operation. 

 

CE MARKING 

 
This equipment complies with the requirements relating to electromagnetic 
compatibility, EN 55032/35 class A  for ITE, the essential protection requirement of 
Council Directive 2014/30/EU on the approximation of the laws of the Member States 
relating to electromagnetic compatibility. 
 
Company has an on-going policy of upgrading its products and it may be possible 
that information in this document is not up-to-date. Please check with your local 
distributors for the latest information. No part of this document can be copied or 
reproduced in any form without written consent from the company. 

 

 

 

Содержание RP-IPG814-2F

Страница 1: ...dential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This device complies with Part 15 of the FCC Rules Operation...

Страница 2: ...to your PD devices All 16 ports are independent and can all be used for easy expansion of your network application With our unique Cold Design technology it will not only power up your PD and also red...

Страница 3: ...h 3 power input sources P1 P2 and P3 To connect power Follow the printed polarity for P1 P1 P2 P2 and ground Connect positive wires to P1 and or P2 connect negative wires to P1 and or P2 and connect t...

Страница 4: ...o place Or Connect the P3 power DIN from external power adapter WARNING Always SHUT OFF power source to connect power wire WARNING Always ground the power source to maintain a clean power input Cheapl...

Страница 5: ...g TX port is active F15 F16 Green ON F15 or F16 SFP fiber is detected OFF F15 or F16 SFP fiber is not detected Flashing F15 or F16 SFP fiber is active P1 Green ON P1 P1 is connected P2 Green ON P2 P2...

Страница 6: ...ion Auto MDI MDI X function Full Half duplex 14 x Gigabit POE 802 3at af PSE port 30W per port 2 x SFP 1000M Network Cable UTP STP Cat 5e or above Cable EIA TIA 568 100m Protocol CSMA CD LED PW1 Green...

Страница 7: ...m 2 Solid wire AWG 12 24 14 22 Stranded wire AWG 12 24 14 22 Torque 5lb In 0 5Nm 0 56Nm Wire Strip length 7 8mm Operating Temperature 40 C to 75 C Operating Humidity 5 to 95 Non condensing Storage Tem...

Страница 8: ...8 Housing Dimension mm...