Dip switch function 

 

 

This unit is equipped with dip switches, located on the front panel. Adjusting the dip switches 
will change the default function of this unit. This unit has set to manufacturer default as:  SFP 
speed 1000M.

 

 

The table shown as you may change the dip switch setting to your desired environment. 

 

 

 

 

LED indicator

 

 
 
 
 
 

 
 
 

 
 

 

 

PWR (Green)

 

ON – Power is detected

 

OFF – Power is not detected

 

SFP Lnk/Act (Green)

 

ON – FX port is detected

 

Flashing – FX data is 
transmitting/receiving

 

Lnk (Green)

 

ON – TX link is detected

 

Flashing – TX data is 
transmitting/receiving

 

PoE (Amber)

 

ON – PD is detected on 
designated port

 

OFF – no PD is detected

 

Содержание RP-IMC811FP

Страница 1: ...likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation CE MARKIN...

Страница 2: ... environment 40 C to 75 C Introduction This Rugged Industrial PoE Media Converter is designed with hardened Marvell IC delivering 30Watts of PoE power to your PD while tolerating extreme temperatures in a harsh environment Our Cold Design technology will not only power up your PD device but also reduce the excessive heat problem to a minimum It accepts input voltages from 48VDC to 56VDC to meet IE...

Страница 3: ...e wire to V connect negative wire to V and connect neutral wire to ground V is for power input connection this unit has only one power input RLY is for relay connection Power connecting procedure STEP 1 Take out 4 pin terminal block located in the included mounting kit package STEP 2 Connect power wire to V with correct polarity and connect RLY for relay Connect the grounding wire to the ground sc...

Страница 4: ... as SFP speed 1000M The table shown as you may change the dip switch setting to your desired environment LED indicator PWR Green ON Power is detected OFF Power is not detected SFP Lnk Act Green ON FX port is detected Flashing FX data is transmitting receiving Lnk Green ON TX link is detected Flashing TX data is transmitting receiving PoE Amber ON PD is detected on designated port OFF no PD is dete...

Страница 5: ...Cat 5e Cable EIA TIA 568 10 ohm 100m Protocol CSMA CD LED PWR Green ON Power is detected OFF Power is not detected SFP Lnk Act Green ON FX port is detected Flashing FX data is transmitting receiving RJ 45 port Lnk Act Green ON TX port is detected Flashing TX data is transmitting PoE Amber ON PD is detected on designated port OFF no PD is detected PoE Pin Assignment 30 watts 2 pairs Mode A End Span...

Страница 6: ...Torque 5lb In 0 5Nm 0 56Nm Wire Strip length 7 8mm Operating Temperature 40 to 75 Operating Humidity 5 to 95 Non condensing Storage Temperature 40 to 85 MTBF mean time between failure 510 304 hrs MIL HDBK 217F at 25 C Housing Rugged Metal IP30 Protection Case Dimension L X W X D mm 103 5mmx32mmx81 5mm LxWxD Installation mounting DIN Rail and Wall Mount options included Certifications Safety UL 609...

Страница 7: ...ng Dimension mm NOTE Housing dimension is for purpose of showing product Length Width Height din rail and terminal block s position and dimension Please reference the LED Indicator Page for correct port order ...