background image

 

 

Smart 10/100BASE-TX to 

  100BASE-FX Fast Ethernet   

Single Fiber Bi-Direction   

Media Converter 

 

Quick Installation Guide 

 

Содержание RP-13SC20S

Страница 1: ...Smart 10 100BASE TX to 100BASE FX Fast Ethernet Single Fiber Bi Direction Media Converter Quick Installation Guide ...

Страница 2: ......

Страница 3: ...frequency energy and if not installed and used in accordance with this user s guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a Class B product In a domestic environment this product may...

Страница 4: ...two wavelengths This design avoids the budget losses incurred b the single wavelength single fiber technology and minimizes any possibility of reflections in the system The units on both ends of a link are different One module uses one wavelength to transmit and a second wavelength to receive while the other module flips that relationship For this reason these units are sold in pairs About Media C...

Страница 5: ...ed switch or hub that is sending the link LLCF can be used for either the copper or fiber ports When LLR is enabled the fiber port s transmitter shuts down if its receiver fails to detect a valid receive link If one of the optical conductors is bad the card with LLR enabled will return a no link condition to its link partner LLR is used to detect link problems only on the fiber port ...

Страница 6: ...k pressure IEEE 802 3x compliant flow control 9 Full wire speed forwarding rate 9 Front panel status LEDs 9 Used as a stand alone device or with a chassis 9 Hot swappable when used with a chassis 9 Supports Link Pass Through 9 Supports Auto MDIX for 100BASE TX port 9 Sliding switch for the duplex mode of Fiber 9 Sliding switch for setting to Forced mode or Auto negotiation 9 Sliding switch for set...

Страница 7: ...quirements 1 The ambient temperature should be between 32 and 104 degrees Fahrenheit 0 to 40 degrees Celsius 2 The relative humidity should be less than 90 percent non condensing 3 Surrounding electrical devices should not exceed the electromagnetic field RFC standards for IEC 801 3 Level 2 3V M field strength 4 Make sure that the equipment receives adequate ventilation Do not block the ventilatio...

Страница 8: ...n Fiber Half Duplex Switch 1 Off Fiber Full Duplex On TX Forced Mode Switch 2 Off TX Auto Negotiation When switch to Forced Mode the Auto MDI X function will turn off and become MDI mode On TX 10M Switch 3 Off TX 100M On TX Half Duplex Switch 4 Off TX Full Duplex On LLR Enable Switch 5 Off LLR Disable On LLCF Enable Switch 6 Off LLCF Disable 6 ...

Страница 9: ...rew and pull out the media converter board First install the converter onto a carrier supplied with the chassis Step 1 Unscrew the carrier from the desired expansion slot on the chassis Step 2 Remove the screw on the converter as shown below Step 3 Fit the converter onto the carrier and use the screw to secure it 7 ...

Страница 10: ...t the Fiber and UTP FDX HDX UTP Auto negotiation Manual Speed 10M 100M LLR Enable Disable LLCF Enable Disable Device Link Setup To enable or disable the connection of both UTP port and Fiber port LLCF Setup To enable or disable the LLCF function of the device M1 AN Setup To set the UTP to Auto negotiation or Forced Mode M1 Speed Setup To set the speed of UTP to 10M or 100M M1 DUP Setup To set the ...

Страница 11: ... in half duplex mode FDX COL Blinking Data collision Lights on A valid network connection established Lights off Not Linking LINK ACT Blinking Data transmitting or receiving Lights on The physical line is broken FAIL Lights off The physical line is fine Dual Wavelength Single Fiber The converter combine transmit and receive signal onto one fiber strand using two kind of wavelength The units on bot...

Страница 12: ...the TX transmit is 1310nm and the RX receive is 1550nm then the other end need to have a combination of converter that the TX transmit is 1550nm and the RX receive is 1310nm The TX needs to connect to the other end s RX with the same wavelength TX 1310nm RX 1550nm TX 1550nm RX 1310nm Media Converter 1 Media Converter 2 10 ...

Страница 13: ... 3 Cable 1 9 125um single mode fiber optic cable UTP Cable L L C F Off L L R On Link 1 Link 2 Link 4 Link 3 Link 6 Link 5 Link Fail 3 Link Fa il 4 Link Fail 2 L L C F Off L L R Off Link Fail 1 Test Result Link Status Disconnect Link 1 Link 2 Link 3 Link 4 Link 5 Link 6 Link Fail 1 LED Link Fail 2 LED Link Fail 3 LED Link Fail 4 LED Cable 1 Off On Off On On On On Off On Off Cable 2 On Off On On Off...

Страница 14: ...he LLCF function of the media converter MC113S TS C Fiber MC115STS C Fiber S W8P B S W8P A UTP Cable Copper Copper Copper Copper Ca ble 2 Cable 3 Cable 1 9 125um single mode fiber optic ca ble UTP Ca ble L L C F On L L R Off Link 1 Link 2 Link 4 Link 3 Link 6 Link 5 Link Fa il 3 Link Fail 4 Link Fail 2 L L C F Off L L R Off Link Fail 1 Test Result Link Status Disconnect Link 1 Link 2 Link 3 Link 4...

Страница 15: ... COL LINK ACT FAIL Speed Fiber FDX COL LINK ACT FAIL Cable 10BASE T 2 pair UTP Cat 3 4 5 up to 100 m 100BASE TX 2 pair UTP Cat 5 up to 100 m 100BASE FX 10 125um single mode fiber optic cable Dimensions L120 W88 H25 mm Power External power adapter 7 5V 1 5A Power Consumption 3W Max Operating Temperature 0 C 40 C 32 F 104 F Storage Temperature 25 C 70 C 13 F 158 F Humidity 10 90 non condensing Emiss...

Отзывы: